Acer Altos R700 Series Bedienungsanleitung Seite 80

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 135
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 79
4 Configuration Software and Utilities
70
3 In the PEM window, click Configure LAN and fill in the boxes
described in the following steps (boxes that aren’t listed here are
not required for LAN alerts).
4 Select the Enable LAN Alerts check box.
5 (Optional) In the SNMP Community String box, enter a string for
the community field in the Header section of the SNMP trap sent
for an alert. The string must be from 5 to 16 characters.
The default string is public.
6 In the IP Setup box, choose either:
DHCP: the IP address for the server is automatically assigned
by the DHCP (dynamic host control protocol) server on the
network. The Host, Gateway, and Subnet Mask boxes in the
dialog are ignored.
Static: assign the IP address for the server using the Host,
Gateway, and Subnet Mask boxes in the dialog.
7 If you chose Static IP Setup in the previous step, fill in the IP
addressing boxes:
Host IP Address: the IP address of this server.
Gateway IP Address: the IP address of the router for this
server.
Subnet Mask: the IP address for the server’s subnet. The server
uses this to decide if the alert destination is on the same
subnet.
8 In the Alert IP Address box, fill in the IP address of the system you
want to receive alerts from this server. If you want the alert to be
broadcast to an entire subnet, enter the IP address for the subnet.
9 From the Options menu, choose Configure Event Actions.
10 In the BMC LAN Alerting Actions window, move the events that
you want to generate an alert to the Enabled column and move all
other events to the disabled column using the following buttons:
>>: Moves all events from the enabled list to the disabled list.
>: Moves the selected event from the enabled list to the
disabled list.
<: Moves the selected event from the disabled list to enabled
the list.
<<: Moves all events from the disabled list to the enabled list.
BS811.f/cppl!!Qbhf!81!!Uvftebz-!Opwfncfs!37-!3113!!21;19!BN
Seitenansicht 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 134 135

Kommentare zu diesen Handbüchern

Keine Kommentare