Installing the Mylex Disk Array Controller as the
Secondary UnixWare Controller with UnixWare
7.x/2.1.3
If UnixWare is installed on a Mylex controller, the Mylex Disk Array
Controller driver for UnixWare is already installed in the system. Simply
install the new Mylex Disk Array Controller hardware.
Note
If you are installing UnixWare 2.1.2 as a secondary
controller, please refer to Installing the Mylex Disk
Array Controller as the Secondary UnixWare
Controller with UnixWare 2.1.2 on page 6-8.
If UnixWare is installed on a non-Mylex controller, install the Mylex Disk
Array Controller driver for UnixWare as follows:
Note
If installing onto a system that is SISL capable and
using a SISL capable DAC it is recommended to
disable the SCSI chip driver on the system by entering
the DCU at the appropriate screen then select
Software Device Drivers and disable the appropriate
driver.
1. Insert the Software Kit UnixWare (dak) driver diskette into the floppy
diskette drive, please refer to Creating a Driver Diskette for
UnixWare on page 6-3.
2. Type the following (match case exactly as shown):
pkgadd -d diskette1 dak
The new controller driver is installed.
3. Rebuild the Kernel:
/etc/conf/bin/idbuild -B
4. Reboot the system:
shutdown -i0 -g0 -y