Model G/GB Centrifugal Roof Exhaust Fans
®
WARNING
Correct direction of wheel rotation is critical. Reversed
rotation will result in poor air performance, motor
overloading and possible burnout.
WARNING
The fan has been checked for mechanical noises at the
factory prior to shipment. If mechanical noise should
develop, suggested corrective actions are offered in
the Troubleshooting section.
IMPORTANT
Over tightening will cause excessive bearing wear and
noise. Too little tension will cause slippage at startup
and uneven wear.
Model GB
Pre-Starting Belt Tension Checks
8. Always loosen tension enough to install belts without
stretching, see Figure 9.
9. For units with two groove pulleys, adjust so the
tension is equal in both belts.
10. If adjustments are made, it is very important to check
the pulleys for proper alignment. Misaligned pulleys
lead to excessive belt wear vibration, noise and
power loss, see Figure 10.
Figure 10
Wheel Overlap and Gap Dimensions
Figure 7
G
H
Model G - Overlap in. (mm) H - Gap in. (mm)
G 060-095
3
32 (2)
G 97-163
1
4 (6)
GB 071-161
1
4 (6)
G 183-243
3
8 (10)
GB 180-240
3
8 (10)
GB 260-540
1
2 (13)
Pre-Starting Checks
1. Check all fasteners and set screws for tightness. The
wheel should rotate freely and be aligned as shown
in Figure 7 below.
2. Wheel position is preset and the unit is test run at the
factory. Movement may occur during shipment and
realignment may be necessary.
3. Only G unit - Centering height alignment can be
accomplished by loosening the set screws in the
wheel and moving the wheel to the desired position.
4. Only GB unit - Centering can be accomplished by
loosening the bolts holding the drive frame to the
shock mounts and repositioning the drive frame.
5. Only GB unit - Wheel and inlet cone overlap can be
adjusted by loosening the set screws in the wheel
and moving the wheel to the desired position.
6. Only GB unit - Fan RPM should be checked and
verified with a tachometer.
7. Check wheel rotation (viewing from the shaft side)
by momentarily energizing the unit. Rotation should
be clockwise as shown in Figure 8 and correspond
to rotation decal on the unit. If wheel rotation is
incorrect, reverse two of the wiring leads or check
motor wiring for single phase.
Wheel Rotation
Clockwise
Airflow
Counterclockwise
Airflow
Figure 8
Clockwise
Rotation
All Models
Do not force belt(s). Forcing the
belt(s) will break the cords and
cause belt failure
.
Belts
Figure 9
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11 12

Kommentare zu diesen Handbüchern