Momentus 5400 FDE.4 SATA Product Manual, Rev. C 9
2.9 Power specifications
The drive receives DC power (+5V) through a native SATA power connector.
2.9.1 Power consumption
Power requirements for the drives are listed in table 3. Typical power measurements are based on an average
o
f drives tested, under nominal conditions, at 25°C ambient temperature.
• Spinup power
Spinup power is measured from the time of power-on to the
time that the drive spindle reaches operating speed.
• Seek mode
During seek mode, the read/write actuator arm moves towar
d a specific position on the disk surface and does
not execute a read or write operation. Servo electronics are active. Seek mode power is measured based on
three random seek operations every 100 msecs. This mode is not typical.
• Read/write
power and current
Read/write power is measured with the heads on track, base
d on three 63 sector read or write operations
every 100 msecs.
• Idle mode power
Idle mode power is measured with the drive up to spee
d, with servo electronics active and with the heads in
a random track location.
• Standby mode
During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/
write
electronics are in power-down model
Table 3: DC power
Power dissipation +5V input average (25° C)
Spinup (max) 1.0 amps
Seek 1.54 watts
Read 1.40 watts
Write 1.78 watts
Idle, performance* 1.40 watts
Idle, active* 0.78 watts
Idle, low power mode* 0.67 watts
Standby** 0.22 watts
Sleep 0.22 watts
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
**Standby power is measured at steady state (after 200ms from transition)