Seitenansicht 27
26
R-1200
R-1201
1. Disconnect the power supply cord.
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Remove the one (1) screw holding the base cover to the
oven cavity back plate.
5. Remove the three (3) screws holding the base cover to
the oven cavity front face plate.
6. Open the base cover.
7. Release the two hood lamp sockets from the base cover.
8. Remove the base cover from the oven cavity by pulling
down and moving to the left slightly.
the terminal hole of the oven lamp socket with the small
flat type screw driver.
8. Now, the oven lamp socket is free.
TURNTABLE MOTOR AND FOOD LAMP SOCKETS REMOVAL
TURNTABLE MOTOR
9. Disconnect the wire leads from the turntable motor.
10.Remove one (1) screw holding turntable motor to the
oven cavity.
11.Now the turntable motor is free.
HOOD LAMP SOCKET
9. Screw the hood lamp off from the lamp socket.
10.Disconnect the wire leads from the lamp socket by
pushing the terminal hole of the lamp socket with the
small flat type screw driver.
11. Now, the lamp socket is free.
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Turn the lamp socket and release it from the magnetron
duct.
5. Screw the oven lamp off from the lamp socket.
6. Now, the oven lamp is free.
7. Pull the wire leads from the oven lamp socket by pushing
OVEN LAMP AND LAMP SOCKET REMOVAL
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, IN-
STALL THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU.
Positive lock
®
connector
Oven lamp
socket
Terminal
Wire lead
Terminal hole
Flat type small
screw driver
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
6. Hold the fan duct to the magnetron with the one (1) screw.
7. Reconnect the wire leads to the fan motor, magnetron
and high voltage capacitor, referring to the pictorial
diagram.
Rear View
Side View
Gap
Rotor
Bracket
Stator
Groove joint pliers
Coil
Shaft
Axis
Stator
Rotor
These are the positions
that should be pinched
with pliers
Shaft
Table
Center of
bracket
8. Reinstall the wire leads to the hole of the fan duct.
9. Refer to procedure of "OUTER CASE REMOVAL". And
reverse their procedure. And reinstall the outer case.