Acer R-1200 Wartungshandbuch Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
5
R-1200
R-1201
Electrical Requirements
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE
GROUNDING PIN FROM THE PLUG.
The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more dedicated line, using
a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood
system mounting location.
OVEN DIAGRAM
1. Oven door with see-through window.
2. Door hinges.
3. Waveguide cover.
4. Turntable motor shaft.
5. Oven lamp.
It will light when oven is operating or door is open.
6. Door latches.
The oven will not operate unless the door is
securely closed.
7. One touch door open button.
8. Auto Touch control panel
9. Time display: Digital display, 99 minutes 99
seconds.
10.Ventilation openings.
11.Light Cover.
12.Bottom sash.
13.Removable turntable.
The turntable will rotate clockwise or
counterclockwise.
Only remove for cleaning.
14.Removable turntable support.
15. Power supply cord
3-Pronged Plug
Grounded
Receptacle Box
Grounding Pin
3-Pronged Receptacle
14
7
7
3
4
5
10
2
1
6
11
12
15
9
8
13
10
CONTROL PANEL
NOTE: Some one-touch cooking features such as "MINUTE PLUS" are disabled after three minutes when the oven is not
used. These features are automatically enabled when the door is opened and closed or STOP/CLEAR button is
pressed.
1100
WATTS
NO.
LBS.
OZ.
CUPS
COOK DEFROST
TIMER
CLOCK
KEEP
WARM
ACCENT
LIGHT
TASK
LIGHT
BAKED
POTATOES
RICE
COOK CENTER
GROUND
MEAT
POPCORN
REHEAT
CENTER
FROZEN
VEGETABLES
FROZEN
ENTREES
FRESH
VEGETABLES
HOT
WATER
DEFROST
CENTER
MINUTE
PLUS
POWER
LEVEL
START
STOP
CLEAR
12345
67890
Seitenansicht 6