Acer TS.R760R.011 Datenblatt Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
8
Acer AN1600 F1 Network Storage System Specifications
Technical Specifications
Dimensions
(with bezel)
438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)
Form factor
2U rack mount (with cable arms included)
Weight
(approximate)
Maximum
(All component slots and sockets
fully populated)
38 kg (84 lbs.)
Minimum
(One HDD, power supply, and
processor installed)
27.5 kg (60.6 lbs.)
BTU rating
Maximum
2456.64 BTU/hr.
System inlet
temperature
Operating
0° - 35°C (50° - 95°F) at sea level with an altitude
derating of 1°C per 305 m (1.8°F per 1000 ft.)
above sea level to a maximum of 3050 m (10,000
ft.) with no direct sustained sunlight. Maximum rate
of change is 10°C/hr. (18°F/hr.). The upper limit
depends on the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
Non-operating
-40° - 70°C (-40° - 158°F) maximum rate of change
is 20°C/hr. (36°F/hr.).
Relative humidity
(non-
condensing)
Operating
8 - 90 % relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing
Non-operating
5 - 95 % relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing
Emissions
classification
(EMC)
FCC rating
Class A
Normative standards
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A
Power supply
Rated steady-state power
720 W (at 100 VAC)
720 W (at 200 VAC)
Maximum peak power
720 W (at 100 VAC)
720 W (at 200 VAC)
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 17 18

Kommentare zu diesen Handbüchern

Keine Kommentare