Acer AB460 F1 Bedienungsanleitung Seite 340

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 618
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 339
4 Networking Switch Modules
320
Interval This parameter specifies the time interval for which the
alarm monitors the variable.
Variable This parameter specifies the MIB object on which the
alarm is set.
Sample Type You can set this parameter to an
Absolute Value
or as
just an
Incremental Value
of the timer.
Rising Threshold If the startup alarm is set as
Rising Alarm
and this
threshold is reached, an alarm is raised.
Falling Threshold If the startup alarm is set as
Falling Alarm
and this
threshold is reached, an alarm is raised.
Rising Event Index Indicates the index of the event to be raised when the
R
ISING THRESHOLD is reached.
Falling Event Index Indicates the index of the event to be raised when the
F
ALLING THRESHOLD is reached.
Owner Specifies the owner of the alarm.
Parameter Description