431
BGP MED Configuration
Clicking the MULTI-EXIT DISC tab brings up the BGP MED CONFIGURATION
page, which allows you to configure the MED value for routes learnt
from BGP peers. The parameters for this page are shown in the
following table.
Hold Time
(Seconds)
This parameter specifies the Hold time. This is the timer
interval that a BGP will wait, before it decides that a
connection to the peer is torn down.
Remote AS This parameter represents the remote autonomous
system number.
Advertisement
Interval (seconds)
This parameter specifies the interval in seconds for the
Minimum Route advertisement interval timer.
Status This parameter specifies the status of the entry.
Parameter Description
MED ID This parameter specifies the index for this table.
Parameter Description