Acer T3104 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach PC / Workstation Barebones Acer T3104 herunter. Acer T3104 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 140
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Systems
WEST
ITALY
Carbon dioxide flux meter
Continuous Monitoring
Handbook
Release 10.1
December 2007
FOGO, FURNAS, TERCEIRA, MAMMOTH Horseshoe Lake, San MIGUEL, San VINCENTE, San SALVADOR, Santa ANA, MOUNUN , NYOS.
Açores University, Université Libre de Bruxelles, University of Florida, Consiglio Nazionale delle Ricerche, Colima University, University of Michigan, Santorini Volcano Observatory
USU SAN, MASAYA, POAS, TEIDE, CUMBRE VEJA, ETNA, STROMBOLI, CAMPI FLEGREI, VESUVIUS, SANTORINI.
Tokyo University, Kyoto University, PennState University, U.S.G.S., ITER, Istituto Nazionale di Geofisica e Vulcanologia, Osservatorio Vesuviano
SERVING VOLCANIC COMMUNITY WORLDWIDE
Seitenansicht 0
1 2 3 4 5 6 ... 139 140

Inhaltsverzeichnis

Seite 1 - Handbook

SystemsWESTITALYCarbon dioxide flux meterContinuous MonitoringHandbook Release 10.1 December 2007FOGO, FURNAS, TERCEIRA, MAMMOTH Horseshoe Lake, San

Seite 2 - West Systems Srl

900 mmIn the drawing the top view of the protection box (DHW), the sensor are not showed.PAGE2.2On-Field InstallationTo place the piquets: Unscrew the

Seite 3

PAGE11.6WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007WEST SystemsWEST Systemswww.westsystems.comCon

Seite 4

PAGE11.7MonitorScada software suiteMonitor is a simple application designed to have a quick view of the last days of data.Monitor display the data

Seite 5

PAGE11.8WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007WEST SystemsWEST Systemswww.westsystems.comCon

Seite 6

PAGE11.9QueryScada software suiteThe Query application allows you to exctract the data from the database and to put it an a table in the MS Excel for

Seite 7

PAGE11.10QueryScada software suiteA resume of the query is reported: The column “Records” shows how many record are present in the time interval y

Seite 8

PAGEA.1AirBoxThe air box is an hardware/software interface that convert the signal of Air Temperature/ Relative Humidity gauge and Sonic w

Seite 9

AirBoxPAGEA.2GILL ConnectionsPanel 6+T female connector PCB Pin Pin 1: +V12 RED 5) +12VPin 3: SGND Green 8) Gnd

Seite 10 - WEST Systems

PAGEA.3AirBoxGill sonic wind speed and direction gauge123456789J1GILL female1234567J2Amphenol MaleSignal Ground+VGndRXDTXDAnalog WSAnalog WD+12VWSSGND

Seite 11

AirBoxPAGEA.42 sensors for relative humidity & temperature - Measurement range: 0-100% RH - Absol. RH accuracy: +/- 2% RH (10...90% RH)

Seite 12

PAGEA.5AirBoxRelative Humidity Accuracy0123450 20 40 60 80 100 120%RHError %Silicon Air Temperature and relative humidity gaugeAir Temperature accurac

Seite 13

PAGE2.3On-Field InstallationIn the picture one of the four stand with the 3 piquets. The soil on the picture is not exactly a “soft” soil...In the pic

Seite 14

AirBoxPAGEA.6PCB Layout1) RS485_A2) RS485_B3) +V in4) Ground5) Gill +12V6) Gill TD7) Gill RD8) Gill Gnd9) Ss +5V10) Ss SCK11) Ss Data12) S

Seite 15

PAGEA.7WEST Systemswww.westsystems.comAirBox Two handbookRelease 10.0 November 2007Rain gauge Water filterWater collection funnelbalance / magnetRee

Seite 16

PAGEA.8WEST Systemswww.westsystems.comAirBox Two handbookRelease 10.0 November 2007spirit levellevelling boltsUnscrew the 3 boltsRemove the coverRa

Seite 17

PAGEC.1WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007WEST SystemsJ2 Amphenol 3 + T Pin Female J1 A

Seite 18

CablesPAGEC.2WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007WEST SystemsStandard analog sensor cableC

Seite 19

SpreadSpectrum 2.4 GHz radio telemetryPAGEF.1Global system block scheme.The system described in this handbook is a data trasmission system able to t

Seite 20

SpreadSpectrum 2.4 GHz radio telemetryMaster Center ComputerFluxStation The system is set to trasmit data bidirectionally from the master center up t

Seite 21 - Soil.Box

SpreadSpectrum 2.4 GHz radio telemetryPAGEF.3RS232 cabling specificationsMaster Center ComputerSlaveradio-modemFluxStation Radio linkPoint to point t

Seite 22

Connecting telemetry to the stationRS232 cableDB9 MaleDB9 Female0.5 m9 Pin Female to 9 pin male Pin To Pin RS232 cable:ON +12 +24WESTPOWERPOWER ONPULL

Seite 23

SpreadSpectrum 2.4 GHz radio telemetryON +12 +24WESTPOWERPOWER ONPULL AND SWITCHPOWER OFFCPURUNWESTMMC-SDCPUP1P2AWM3300VBAConnect the antenna out of

Seite 24

PAGE2.4WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.1 November 2007WEST SystemsWEST Systemswww.westsystems.comCont

Seite 25

PAGEF.6SpreadSpectrum 2.4 GHz radio telemetryConnecting the antenna to the stationConnect the coaxial cable to the passtrought connection on the righ

Seite 26

PAGEF.7Setting the radio-modemChange the setting of the radio-modem only when strictly necessary.!Connect the radio-modem to a computer using a standa

Seite 27

PAGEF.8Setting the telemetry.F i r s t c o m m u n i c a t i o n a n d f l u x s t a t i o n - c o m p u t e r synchronization; The FluxStati

Seite 28

PAGEF.9Setting the telemetry.Point to point switched with repeaterOpen Change the TelemetryID field to SSR24 Check that on the telemetry table the rec

Seite 29

PAGEF.10The radio-modem LED LightsCDTXCTSConnectedTrasmitting DataNot ConnectedSlave NOT connectedRepeater NOT connectedSetup ModeMaster LED Status Yo

Seite 30

PAGEF.11The radio-modem LED LightsCDTXCTSConnectedTrasmitting DataNot ConnectedSetup ModeSlave LED Status When you turn on the Slave radio-modem the 3

Seite 31

PAGEF.121234www.westsystems.com459RS232SETCTSTXCDwww.westsystems.com459ANTENNAThe radio modemStatus LED LightsSet button (Press to enter in setup mod

Seite 32

PAGEF.1312345678910J7Radio162738495J10RS232 FEMALES2Set BtnGND+VFWSETGNDTDFWGNDRDFWCDRTSCTSD1024V600WR151KDSRF21AD91N4007C16100n+12V1234J11Power INDTR

Seite 33 - WEST SystemsWEST Systems

PAGEF.12CDTXCTSVery low signalCDTXCTSMedium signalRADIO PARAMETERS(0) FreqKey 5(1) Max Packet Size 8(2) Min Packet Size 9(3) Xmit R

Seite 34

Please note that the soilbox is designed to works only with the CS616 CS water content TDR probe. The obsolete CS615 can not be used.PAGES.1WEST Syste

Seite 35

PAGE2.5Power supply10Battery -Battery +FL-I007RS485/1 RS485/2 RS485/3 BatteryCH 2/3CH 4/5Acc.Ch.Aux.1AntennaAux.2www.westsystems.comCEfrom Solar CellA

Seite 36

SoilBoxPAGES.2WEST Systemswww.westsystems.comSoil Temperature Pt100 ConnectionsPanel 3+T female connector Pin 1: Red 1 Pin 2: Red 2 Pin

Seite 37

PAGES.3WEST Systemswww.westsystems.comSoilBox handbookC1+1C1-3C2+4C2-5V+2V-6VCC16T1IN11T1OUT14T2IN10T2OUT7R1OUT12R1IN13R2OUT9R2IN8GND15U5ST232CDC35100

Seite 38

SoilBoxPAGES.4WEST Systemswww.westsystems.comPCB LayoutHUB2004.DDBSoliBox Rel 2.00 SystemsWEST W2 W1 R2 R1+12VSGreenGnd GndBA +12V186 +12V2 A1 GndGndG

Seite 39

PAGES.5WEST Systemswww.westsystems.comSoilBox handbookRelease 6.9 October 2004SoilBoxSoil water content6+T Male cable connector (To the SoilBox)Pi

Seite 40 - The accumulation chamber

PAGES.6WEST Systemswww.westsystems.comSoilBox handbookRelease 6.9 October 2004Soil temperatureManufatcurer : RSOrdering code :RS 321-6090Type : Pt100

Seite 41

PAGEZ.1PDA software installationThe SetStation software is furnished by WEST Systems on two different support format:!On the WEST Systems software CD

Seite 42

PAGEZ.2Software installationNow tap and hold in the white area of "Start menu" folder until a flying menu will appear.File explorerStart me

Seite 43 - PDA RS232 cable

PAGEZ.3Scada software installationThe Scada software is furnished by WEST Systems on the WEST Systems software CD. Run ScadaSetup.msiThe Sc

Seite 44 - File Parameters

PAGEZ.4FluxStation handbookRelease 10.0 December 2007WEST Systemswww.westsystems.comFluxStation handbookRelease 10.0 December 2007WEST Systemswww.

Seite 45

© www.westsystems.comContinuous monitoringRelease 10.1 December 2007FluxStation HWR8 and Scada software suiteHandBook 10.0 released on November 2007S

Seite 46

PAGE2.610Solar cell charge regulatorThe LED light is ON when the solar cell is exposed to sunlightThe LED light is:Green when the battery is full Yell

Seite 47

WEST Systems© www.westsystems.comContinuous monitoringRelease 10.1 December 2007

Seite 48 - Open acc.chamber time

PAGE2.7bp_fff007BrombachPumpASF THOMASASF THOMASpin-007RS232 CH2CH3 CH1 CH0Power APumpBatteryRS485www.westsystems.comON +12 +24WESTPOWERPOWER ONPULL A

Seite 49 - Radio OFF time: 900 sec

PAGE2.8The external sensors connections:The FluxStation is supplied with several meterological and soil parameters sensors:!Air temperature a

Seite 50

PAGE2.9To Gill Anemometerusing the Gill cable (page A.3)To Rain GaugeSee page A.2To FluxStation , using a RS485 cable. RS485/1 connectorThe air box

Seite 51

Soil water content CS616 (Page 4.7)Soil temperature probe (Page 4.8)SoilBox (Appendix S)PAGE2.10RS485 TDR Pt100 To FLuxStation RS485/2 connector,

Seite 52

PAGE2.11sot-07sop-05AuxLinakFanTo Aux 1To Acc. Ch.FL-I007RS485/1 RS485/2 RS485/3 BatteryCH 2/3CH 4/5Acc.Ch.Aux.1AntennaAux.2www.westsystems.comCEClose

Seite 53

West Systems SrlIf your equipment requires maintenance in Italy:BEFORE YOU SHIP THE INSTRUMENT BACK TO ITALY REMEMBER:!When you ask your shipping agen

Seite 54

PAGE2.12On-Field InstallationAccumulation chamber Place the collar and fill again the hole , taking care off the sealing of the collar. 1_r

Seite 55

PAGE2.1310Battery -Battery +FL-I007RS485/1 RS485/2 RS485/3 BatteryCH 2/3CH 4/5Acc.Ch.Aux.1AntennaAux.2www.westsystems.comCEfrom Solar CellAmp. 6+T Mal

Seite 56 - Press Enter key to proceed

Accumulation chamber tubessot-07sop-05FanLinakCloseSwFL-I007RS485/1 RS485/2 RS485/3 BatteryCH 2/3CH 4/5Acc.Ch.Aux.1AntennaAux.2www.westsystems.comCERe

Seite 57

Pump Pneumatic circuitPump specificationsRated flow: 1000 SCCM (Standard cubic centimeter per minute) Power supply 150 mA @ 12 Volts Manufacturer KNF

Seite 58

-Vin2-Vin3+Vin22+Vin23Com9-Vout-d11+Vout-s/d14Com / -Vout-s16DC1TEN3-1212C11uF+VIN_prot-VINC21uF-PumpD1 18V 600WF1Fusibile Rip. 500mA+VINGnd+PumpThe p

Seite 59

P1P2AWM3300VBABrombachPumpASF THOMASASF THOMASInletOutletFilter>>All the internal connections are made with silicon tube 8 mm external diameter

Seite 60

M10 x 1mmWEST Systems Tube fitting for RILSAN 6x4 and Silicon tubesMaterial : Chromed brass2.8 mm DiameterThe fittings44 mm25 mm3 types of tube are us

Seite 61

Carbon dioxide detectorSensorsDRAGER Polytron IR CO Specifications2 Working principles: Double beam IR Detector with solid state sensor compensated

Seite 62

Carbon dioxide detector internal connectionsSensorsCarbon dioxide detector setup For the setup of the correct full scale please refer to pages 56-57 o

Seite 63

Barometric pressure gauge PT100BSensorsMaximum working elevation 4000 metersManufatcurer : VAISALAOrdering code :VAISALA-PT100BRange 600-1060 HPa (mB

Seite 64

WEST Systemswww.westsystems.comPortable flux meter handbookRelease 7.00 -FluxManager- July 2007INDEXWEST SystemsINDEXChapter Argument Page1List of t

Seite 65

SensorsGas line flow meterManufatcurer : WEST Systems (Sensor made by Honeywell-SensorTechnics)Ordering code :AWM3300Gas flowRange 0 to 1300 SCCMAcc

Seite 66

Soil water contentSensors6+T Male cable connector (To the SoilBox)Pin 1 : Red +12 VoltPin 2 : Orange Ignition Pin 3 : Green Frequency signal

Seite 67

SensorsSoil temperatureManufatcurer : RSOrdering code :RS 321-6090Type : Pt100 DIN IEC 751 Class B 4 wiresRange 0 to 200 °C Max operating temperatur

Seite 68

Gas concentrationTimeCAirCSoilConcentration increase ppm/secThe flux is proportional to the concentration increase ratio ppm/sec. The proportionality

Seite 69

K=86400P106R TkVAWhere ! P is the barometric pressure expressed in mBar (HPa)-1 -1! R is the gas constant 0.08314510 bar L K mol! T is the air tempe

Seite 70

The accumulation chamberPAGE5.3In the following table the factors for the conversion from ppm/sec slope to -2 -1moles m day are reportedBar. Press

Seite 71

The accumulation chamberPAGE5.4In the following table the factors for the conversion from ppm/sec slope to -2 -1grams m day are reportedBar. Press

Seite 72 - Mass flow controller

PAGE5.5The accumulation chamberThe accumulation chamberThe flux curve is no longer "linear", the linear best fit curve do not fit exactly

Seite 73

PAGE5.6sot-07sop-05570480The accumulation chamberFoot print size1_rf2_rfbr-05VVENT-04VVENT-04WEST SystemsWEST Systemswww.westsystems.comContinuous mon

Seite 74

PAGE5.7The accumulation chamberCable AC1Bulgin 6 pin male Amph 6+T pin femaleCable AC1Bulgin Pin Color Amph Pin1 Black 12 White 23 Blue 34 Yellow 45 R

Seite 75

WEST Systemswww.westsystems.comPortable flux meter handbookRelease 7.00 -FluxManager- July 2007INDEXINDEX7 Running FluxStationGeneral considerations

Seite 76

PAGE5.8The accumulation chamber1234567J9F_LINAK1234567J10F_FANL210W 12V RS579219FAN+FAN+EV6EV6VDCVDCEnBrownEnBlueEnBlueEnBrownD3AC_BlueD4AC_BrownD2FAN

Seite 77

PAGE5.9The accumulation chamberTwo proximity switches control the full opening and full closing of the accumulation chamber.Type: inductive proximity

Seite 78

PAGE5.10sot-07sop-05AuxLinakFanTo Aux 1To Acc. Ch.FL-I007RS485/1 RS485/2 RS485/3 BatteryCH 2/3CH 4/5Acc.Ch.Aux.1AntennaAux.2www.westsystems.comCEClose

Seite 79

PAGE6.1pin-007RS232 CH2CH3 CH1 CH0Power APumpBatteryRS485www.westsystems.comON +12 +24WESTPOWERPOWER ONPULL AND SWITCHPOWER OFFCPURUNWESTMMC-SDCPUP1P2

Seite 80

PAGE6.2Palmtop (PDA) SetStation application Flux Station configuration/testingSetStation 1.2File ParametersCommunication portConnected Station IPStatu

Seite 81

PAGE6.3SetStation 1.2DigitalDisplay readings formFlux Station configuration/testingPump OnAC UpAC downRS485 scanFormat SDSD StatusSample nowSet ClockR

Seite 82

PAGE6.4SetStation 1.2DigitalPump OnAC UpAC downRS485 scanFormat SDSD StatusSample nowSet ClockRadio On350.45CO2 ppm1013.45Bar.P.mBar0.00Ch.2 mACh.3 mV

Seite 83

PAGE6.5SetStation 1.2File ParametersCommunication portConnected Station IPStatusStation DateSet AllGet All>COM1 Serial Cable on COM10.1idle refresh

Seite 84

PAGE6.6Analisys every time It's the interval between analisys. Normally the station makes an analisys every hour and then the default value of

Seite 85

PAGE6.7Set RADIO On/OFF:In order to reduce the power consuption the telemetry system is managed as follow:RADIO On time (sec)The telemetry system will

Seite 86

PAGE1.1The package contentsWEST Systemswww.westsystems.comGoods Description S/n Quantity CheckSensors Polytron IR CO2 DRGEEX02 1Vaisala Pt100 C1130006

Seite 87

PAGE6.8Num. Samples: Is the number of points in the flux record. Normally the value is between 32 and 256 points. The increase of this parameter will

Seite 88

PAGE6.9SetStation 1.2File ParametersCommunication portConnected Station IPStatusStation DateSet AllGet All>COM1 Serial Cable on COM10.1idle refresh

Seite 89

PAGE6.10SetStation 1.2File ParametersCommunication portConnected Station IPStatusStation DateSet AllGet All>COM1 Serial Cable on COM10.1idle refres

Seite 90

PAGE6.11Channels parameters Flux Station configuration/testingName: is a description of the channel, to help the operator.Conf: Is the type of cha

Seite 91

PAGE6.12Changing the Drager Polytron IR CO2 full scale value.SetStation 1.2Set AllOkChannel #0 secCO2 ppmNameokGet completed!Get SetFF06Conf (Hex) Get

Seite 92

PAGE6.13Changing the Drager Polytron IR CO2 full scale value.Press the DN key twice to set the password = 2 then press enter to confirmPASSWORD?2Now

Seite 93

PAGE6.14NEW CONFIGURATIONSTORED!Press Enter key to proceedPress Esc twice and Enter to come back at the measurement.CONFIGURATION:GAS CONFIGURATIONRem

Seite 94

WEST SystemsPAGE7.1WEST Systemswww.westsystems.comContinuous monitoring device handbookpin-007RS232 CH2CH3 CH1 CH0Power APumpBatteryRS485www.westsyste

Seite 95

WEST SystemsPAGE7.2WEST Systemswww.westsystems.comContinuous monitoring device handbookpin-007RS232 CH2CH3 CH1 CH0Power APumpBatteryRS485www.westsyste

Seite 96

WEST SystemsPAGE7.3WEST Systemswww.westsystems.comContinuous monitoring device handbookCPURUNWESTMMC-SDCPUBefore to insert the SD memory card in the C

Seite 97

Safety informationDiffuse carbon dioxide fluxes are normally related to anomalous carbon dioxide air concentration. The user must verify the safety

Seite 98

WEST SystemsPAGE7.4WEST Systemswww.westsystems.comContinuous monitoring device handbookQuasi-continuous monitoringRunning FluxStation After inserting

Seite 99

WEST SystemsPAGE7.5WEST Systemswww.westsystems.comContinuous monitoring device handbookpin-007RS232 CH2CH3 CH1 CH0Power APumpBatteryRS485www.westsyste

Seite 100

WEST SystemsPAGE7.6WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Release 10.0 November 2007

Seite 101

CalibrationsPAGE8.1General discussionCalibration control example:Before verifying the calibration turn on the detectors using the PDA and Set

Seite 102

PAGE8.2Calibration of Drager IR CO2! A cylinder of nitrogen or synthetic UPP Air, or a SODA LIME trap or a DRAGER PIPE to trap the carbon dioxide.! A

Seite 103

PAGE8.3Calibration of Drager IR CO2Press the enter key, then the display will ask to enter the passwordPress the DN key twice to set the password = 2

Seite 104

Calibration of Drager IR CO2Wait that the reading is stable then select Y by pressing the left arrow key then press the enter key. Press the Enter

Seite 105

Calibration of Drager IR CO2Now you have to set the value of the concentration of CO2 in the gas mixture you'll use for the calibration. Usin

Seite 106

Calibration of Drager IR CO2www.westsystems.comRelease 5.39 December 2005PAGE8.6STOP GAS FLOW? Y/NSelect Yes and press Enter to proceed.

Seite 107

PAGE8.7Calibration of the 4-20 mA interface of DragerPress the DN key twice to set the password = 2 then press enter to confirmPASSWORD?2Now press t

Seite 108

PAGE1.1WEST Systemswww.westsystems.comBefore to start the installation of the FluxStation is better to install the Master center telemetry systems

Seite 109

NEW CALIBRATIONFACTOR STORED!Press Enter key to proceedCalibration of the 4-20 mA interface of Drager40 mV Value OK?Y/NThe drager ask 40 mV value OK?

Seite 110

PAGE8.9WEST Systemswww.westsystems.comPortable flux meter handbookRelease 10.0 December 2007WEST Systemswww.westsystems.comPortable flux meter handbo

Seite 111 - Reed ampolla switch

Calibration of the flux meterFluxmeter calibrationHow to verify the fluxmeter calibrationAs the computation of flux is a function of the gra

Seite 112 - Remove the cover

PAGE8.112 2For fluxes between 300 moles/(m day) and 700 moles/ (m day) the injected flux is controlled by means of a mechanical flow reducer and meas

Seite 113

The influence of pumping flowIn the diagram the plot of the measurement error versus the imposed flux of carbon dioxide (expressed in grams per s

Seite 114

PAGE8.13RPM vs battery voltage0204060801001201400 2 4 6 8 10 12VoltRPMIn the plot the measured flux vs the mixing device rotation speed. In th

Seite 115

PAGE8.14WEST Systemswww.westsystems.comPortable flux meter handbookRelease 10.0 December 2007WEST Systemswww.westsystems.comPortable flux meter handb

Seite 116

PAGE9.1Databases structureAll the information necessary to run scada, as well as the data acquired by the fluxstation, are stored in a single file : s

Seite 117

PAGE9.2The four applications of Scada suite read the system DSN from the ODBCName.txt file, located in the C:\WEST\scada\source\ folder T

Seite 118

PAGE9.3Database scada_data.mdbScada_data.mdb is composed by several tables, some of them are to define the fluxstations and their configuration. Some

Seite 119

PAGE1.2WEST Systemswww.westsystems.com

Seite 120

PAGE9.4Each FluxStation must be defined in the Stations table.Field Value DescriptionID 13 Record ID (Counter)Active -1 -1 = Active // 0 Not activeNe

Seite 121

PAGE9.5The Site, Latitude, Longitude, Elevation and Responsible fields contain only descriptive data. Type and Model are critical parameters that indi

Seite 122

PAGE9.6ID StationID Number Name FullScale LowScale Gain Offset Statistics PlotCurve Conf Type47 OVK01 0 CO2 20000 0 1 0 1 -1 FF06 ANALOG48 OVK01 1 Bar

Seite 123

PAGE9.7Databases structureDatabase scada_data.mdbChannels tableThe Channels table is derived from the PhisicalChannels one, integrated with additional

Seite 124

PAGE9.8Databases structureDatabase scada_data.mdbTelemetry tableThe Channels table is derived from the PhisicalChannels one, integrated with additiona

Seite 125

PAGE9.9RS232The base type RS232 supports several TelemetryTypes: GSM: Gsm based data modems;SSR24: Spread spectrum 2.4 or 0.9 GHz in switched mode;RS2

Seite 126

PAGE9.10WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007WEST SystemsWEST Systemswww.westsystems.comCon

Seite 127

WEST SystemsPAGE10.1WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007The software suite of Scada is compo

Seite 128

WEST SystemsPAGE10.2WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007PC ClockScada applicationScada softw

Seite 129

WEST SystemsPAGE10.3WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Scada applicationScada software suit

Seite 130

PAGE2.1On-Field InstallationInstallationSelect the installation site after a carbon dioxide flux survey. The best location is in the middle of an

Seite 131

WEST SystemsPAGE10.4WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Scada applicationScada software suit

Seite 132

WEST SystemsPAGE10.5WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Scada applicationScada software suit

Seite 133

WEST SystemsPAGE10.6WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Scada applicationScada software suit

Seite 134

WEST SystemsPAGE10.7WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Scada applicationScada software suit

Seite 135 - ACER n300

WEST SystemsPAGE10.8WEST Systemswww.westsystems.comContinuous monitoring device handbookRelease 10.0 November 2007Scada applicationScada software suit

Seite 136

PAGE11.1Flux revisionScada software suiteFluxrevision allows the checking of flux curves acquired by the station.Select your station.Select the initia

Seite 137

PAGE11.2Flux revisionScada software suiteTo see the flux curve click on the list.The flux curve On the right part of the form is reported the informat

Seite 138

PAGE11.3Modify the limits by dragging the vertical lines in the desired position. The flux, the slope and the ErrQ will be automatically updated. T

Seite 139 - © www.westsystems.com

PAGE11.4Flux revisionScada software suiteAutomatic computation of flux.FluxRevision can compute the flux following 3 different algorithms: By selectin

Seite 140

PAGE11.5Flux revisionScada software suiteBatch processingBy clicking on [Sampling Date] you can order the list by date in ascending or descendin

Kommentare zu diesen Handbüchern

Keine Kommentare