NetWare 4.11 – Secondary Controller
This section describes how to integrate a DPT SmartRAID VI controller
into a new or existing Novell NetWare 4.11 system as a secondary
controller. Ensure that your NetWare version is at the minimum patch
level specified by Novell.
NOTE The server must have patch kit IWSP4 or later installed to use
the drivers supplied by DPT. NetWare 4 Support Pack 8
contains the latest Novell I
2
O drivers. These drivers are newer
than the ones from DPT but have not been tested for
compatiblity with DPT controllers.
To integrate a DPT controller into a existing Novell NetWare 4.11 system,
do the following:
1. Download the NW411.ZIP file from the DPT Technical Support web
site. Extract the files to a floppy disk.
2. Shutdown the server and switch off the power. Install the DPT
controller and any attached storage devices as a secondary disk
subsystem. Note the slot used by the controller, you will need this
information later in the install process.
3. Power on the server and use SMOR to configure the storage
subsystem. Press Ctrl+D during boot to start SMOR.
4. Start NetWare. When the console prompt appears type, LOAD
INSTALL and press Enter.
5. Select PRODUCT OPTIONS and press Enter.
6. Select INSTALL A PRODUCT NOT LISTED and press Enter.
7. Insert the diskette you created in drive A: and install I2O and
BLOCK STORAGE support only.
8. Accept the defaults for the remaining install options.
9. Return to the main install screen and select NCF OPTIONS.
10. Select EDIT STARTUP.NCF.
Ensure that BKSTROSM.HAM is listed after I2OPCI.NLM.
11. Shutdown and restart the server.