Seitenansicht 120
6-9
Storage Manager
Building
Status flag: blue - This flag appears on an array icon
when an array that was created is being built.
Status flag: white - This flag appears on the drive icon
that data will be copied to in a RAID 1 array build.
Failed
Status flag: red - This flag appears on a drive icon
when the drive has failed.
On an array icon, this flag indicates that one drive has
failed in a RAID 0 array or two or more drives have
failed in a redundant array.
Impacted
Status Flag: white - The array is in a degraded mode
but no host I/O request has occurred since the
degraded status was reported.
Missing
Status flag: black - This flag appears on a drive icon
when the drive is physically missing or will not
respond to commands on the peripheral bus.
On an array icon, this flag indicates that the array has
been created or modified within Storage Manager but
the array has not yet been built.
On a Hot Spare icon this flag indicates that the Hot
Spare has not yet been created by the controller.
Optimal
Status flag: none - The drive or array is fully
functional and is not running any operations that
impact performance.
Pending
Status flag: blue - This flag appears on an array icon
when the array has been created and the build is
queued on the controller, but is not yet started.
Rebuilding
Status flag: blue - This flag appears on an array icon
when the array is being rebuilt after a drive failure.
Status flag: white - This flag appears on a drive icon
when data is being rebuilt onto that drive.
Verifying
Status flag: white - This flag appears on drive or array
icons to indicate that redundancy is being verified on
the array. Performance may be affected.
Warning
Status flag: yellow - This flag appears on a drive icon
(with S.M.A.R.T. failure prediction) to indicate that
failure may be imminent.
This flag appears on a RAID 1 or RAID 5 array that
has a failed or missing drive.