Acer SmartRAID V Bedienungsanleitung Seite 151

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 256
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 150
6-39
Storage Manager
Drive Failures
Drive failures are indicated by flags on the icons associated with the Array
Group, array and individual drives. Failure conditions are indicated as
follows:
A drive belonging to an Array Group fails
The drive icon displays a red flag in both the Physical and Logical
Configuration Views.
The failed drive belongs to a RAID 0 Array Group
The icon for the failed drive displays black flag. Loss of any drive in a
RAID 0 array means the array has failed and data on that array has
been lost.
The failed drive belongs to a RAID 1, 0+1, 5, or 0+5 Array Group
The array icon displays a yellow flag, indicating that the array is
currently running in degraded mode. If two or more drives belonging
to the same array show a red flag, the yellow flag on the array changes
to red, indicating that the array has failed and that data has been lost.
Audible Alarm
DPT controllers with caching capability (Millennium models or Decade/
Century models using an RA4050 module) have an audible alarm. The
failure of a drive which is a member of an array attached to the controller
causes the audible alarm to sound. The alarm stops automatically (after
the initial system scan) when you start Storage Manager or SMOR.
Alarms that occur while Storage Manager is running can be stopped by
selecting OptionsTurn Off Audible Alarms.
Seitenansicht 150
1 2 ... 146 147 148 149 150 151 152 153 154 155 156 ... 255 256

Kommentare zu diesen Handbüchern

Keine Kommentare