Rebuilding a Degraded Array
NOTE You can select Rebuild even if the failed drive has not been
replaced and try using the drive again. If the rebuild attempt is
not successful, replace the drive before starting another
rebuild.
When a drive in a RAID 1 or RAID 5 array fails, and that drive is not
protected by a Hot Spare, do the following to restore the array to Optimal
status:
1. Replace the failed drive according to the procedure in your
hardware documentation.
2. After the failed drive has been replaced, choose the Logical
Configuration View in Storage Manager.
3. Double click the array group icon to open the Array Group
Information window.
4. Click Rebuild in the Array Group Information window to start the
rebuild process.
The drive will display a white flag to indicate that a rebuild operation is in
process. The array and LSU icons will display yellow flags. The percentage
completion of the rebuild operation is displayed in the Array Group
Information window. When the rebuild is complete, the flags will disappear
and the array status should be Optimal.
NOTE If you are using a DPT RAIDstation storage cabinet with a
SmartRAID V controller, failed drives can be replaced and
rebuilt without using Storage Manager. RAIDstation storage
cabinets and drives have hot swap (SCA-2) connectors so that
failed drives can be removed or replaced without first quieting
the bus. The RAIDstation subsystem will detect that a failed
drive has been physically replaced and the controller will
automatically start a rebuild operation.