6-42
Storage Manager
Verify
NOTE Data inconsistencies should not occur under normal
conditions. However, a power failure that interrupts an array
write operation can cause inconsistencies. Using the Verify
function to make the data consistent does not ensure that
the new consistent data is the correct data.
Running a Verify operation for RAID 1 and RAID 5 arrays ensures that the
redundant information contained in the array is consistent. This operation
is performed by the SmartRAID V controller concurrent with normal
system operation and requires no user or host computer intervention.
To start data verification on an array, select Verify in the Array Group
Information window.
If any inconsistencies in the data redundancy are found, they are made
consistent.
For RAID 1 arrays, the mirrored drive pairs are compared sector by
sector to ensure that both drives contain identical data.
For RAID 5 arrays, parity is recalculated and checked against the stored
parity information.
For RAID 0, only a disk media ECC check is performed.
Running Verify on an array that is in a degraded state can result in
significantly reduced I/O performance. Although there is no impact on the
host CPU, system I/O performance can be affected due to increased
demand on controller resources. If this is a concern, use the Background
Task Priority feature to assign a lower level priority to background
processes.