7-8
Theory of Operation
HEAVILY LOADED SYSTEM
Without Hardware Cache
Application programs write to OS cache:
Bus
activity:
OS cache flushes to disk (~11ms per write)
Idle
time
Idle
time
HEAVILY LOADED SYSTEM
With Hardware Cache
Application
programs
write to
OS cache
System Bus
activity
OS cache flushes
to SmartRAID
(1ms per write)
Idle
time
Idle
time
SmartRAID
Bus
SmartRAID
elevator-sorted writes to disk
(1-5ms per write)
As an example, consider an operating system with 4MB of dirty data in its
cache buffers. With a 4KB record size and an average disk I/O time of
11ms per record, this flush operation would take 11 seconds. However, with
controller cache installed the entire flush operation from the software
cache would take approximately 1 second instead of 11 seconds. The
SmartRAID V controller can then flush its cache to disk in elevator-sorted
order using its separate I/O bus, concurrently with other system activity.
Elevator Sorting
SmartRAID V cache flush operations occur much faster than from the
operating system cache, because all data in the controller cache is kept in
elevator sorted order. Data is written to disk in order of increasing block
address, minimizing both physical disk seeks and rotational latency. This
feature, called Elevator Sorted Write-back, eliminates much of the head
thrashing commonly associated with disk-intensive operating systems like
Novell NetWare, Windows NT and UNIX. By elevator sorting the sectors in
cache, the average write access time to the drive may be reduced from the
normal 11ms (seek + rotation) time, to between 1 and 5ms.
A good analogy is an elevator in a multistory building. Consider how much
slower the elevator would be if it went to the requested floors in the same
sequence that the buttons were pressed, instead of in floor number
sequence! An additional benefit of elevator sorting is that multiple short
disk write operations can often be coalesced within the controller cache
into one large write operation, significantly reducing peripheral bus
overhead.