7-15
Theory of Operation
RAID 1, also known as disk mirroring, is simply a pair of disk drives that
store duplicate data but appear to the computer as a single drive. Although
striping is not used within a single mirrored drive pair, multiple RAID 1
arrays can be striped together to create a single large array consisting of
pairs of mirrored drives. All writes must go to both drives of a mirrored
pair so that the information on the drives is kept identical. However, each
individual drive can perform simultaneous, independent read operations.
Mirroring thus doubles the read performance of a single non-mirrored
drive and while the write performance is unchanged. RAID 1 delivers the
best performance of any redundant array type. In addition, there is less
performance degradation during drive failure than in RAID 5 arrays.
RAID 1
Mirrored Arrays
Duplicate data is written to pairs of drives.
Reads can occur simultaneously on every drive.
DATA DATA DATA DATA DATA DATA
RAID 2 arrays sector-stripe data across groups of drives, with some
drives assigned to store ECC information. Because all disk drives today
embed ECC information within each sector, RAID 2 offers no significant
advantages over other RAID architectures and is not supported by
SmartRAID V.
RAID 2
Parallel Array with ECC
Each write operation spans all drives.
Each read operation spans all drives.
DATA DATA DATA DATA ECC ECC ECC