7-32
Theory of Operation
Cabling Ultra2 (LVD) SCSI
When the total length of a SCSI cable must exceed the maximum length
for single-ended buses, DPT recommends the use of an Ultra2 Low
Voltage Differential SCSI interface.
The following guidelines will help ensure reliability when configuring
Ultra2 SCSI systems:
Use twisted-pair cable. Twisted-pair cable (either twisted-flat or
discrete wire twisted-pairs) provides greater signal integrity over
longer distances because noise coupled into a twisted-pair generally
appears equally on both wires. Because the differential receivers
respond to differences between the conductors of the twisted-pair, the
coupled common-mode noise is rejected.
Flat non-twisted ribbon cable can cause two problems. First, noise
introduced into parallel conductors tends not to be common mode.
Second, while the single-ended conductor arrangement interleaves
ground wires between signal wires, there are not enough conductors
to interleave grounds between each differential signal pair. These
factors lead to increased crosstalk between adjacent conductors on a
flat non-twisted ribbon cable.
The maximum cable length for an LVD bus is 12 meters (39.3 feet).
Because Ultra2 cables are sensitive to cable capacitance, the following
table of minimum spacing between devices should be followed:
Cable Capacitance Minimum Spacing
40 pF/m 36 cm
65 pF/m 22 cm
90 pF/m 16 cm
115 pF/m 13 cm
140 pF/m 10 cm
Stub lengths should not exceed 0.1 meters (3.9 in.). The difference in
stub length should be less than 1.27 cm (0.05 in.) for the REQ, ACK,
DATA and PARITY signals.
Terminators should be installed only at each physical end of the bus,
either on the last device attached or the unused connector at the end
of the cable. Ultra2 buses must be terminated with LVD terminators.
DPT cables are supplied with an LVD terminator installed at the end
of the cable.