Troubleshooting
Problem: After a flash ROM upgrade of the I
2
O BIOS only, pressing Ctrl+D at the
system prompt displays the message Card not configurable.
Solution: Perform a flash ROM upgrade for SMOR to correct this condition.
Problem: The floppy disk drive cannot be accessed after installing a DPT controller.
Solution: Use SMOR to enable the EBDA Relocation option.
Problem: The controllers audible alarm is sounding during normal operation.
Solution: This indicates a drive has failed. Start Storage Manager or restart the host
system and run SMOR to identify the failed drive. The alarm will stop
when Storage Manager or SMOR finish the system scan. Replace the
failed drive and start a rebuild operation for the array.
For additional information about procedures for failed drives, refer to
Chapter 4, Storage Manager on ROM or Chapter 6, Storage Manager.