2-6
About Your New SmartRAID V Controller
You can use an SX405x Bus Expansion Module to expand a Millennium
controller with one or two additional SCSI channels or with one Fibre
Channel Arbitrated Loop (FC-AL) port. Millennium Fibre Channel
controllers can be expanded with one additional FC-AL port. By using an
SX4055F Bus Expansion Module, Fibre Channel and SCSI buses can
coexist on the same SCSI controller (PM375xU2 models only). SX405x Bus
Expansion Modules are daughter cards that attach to the SmartRAID V
controller and do not require an additional card slot in the host system.
The PM3755U2B controller can be upgraded to include a battery-backed
cache by adding a BB4050 battery module.
For controlling DPT RAIDstation storage cabinets or other
manufacturers cabinets, Millennium SCSI controllers provide a
Very High Density Cable Interconnect (VHDCI) 0.8 mm external
connector.
To simultaneously control SCSI devices mounted in the host system,
Millennium SCSI controllers provide an internal, high-density 68-pin
connector.
The Millennium Fibre Channel controller provides a single High
Speed Serial Data Connector (HSSDC) for external connections. Dual
loop redundancy is available by adding an SX4055F Expansion Module.
The memory sockets on a Millennium controller accept up to 256MB of
cache for maximum performance. For maximum data protection, use the
DPT ECC SIMMs or DIMMs listed below:
Model Description
SM4050-16 16 MB ECC SIMM
SM4050-64 64 MB ECC SIMM
DM4050-16 16 MB ECC DIMM
DM4050-64 64 MB ECC DIMM
DM4060-16 16 MB ECC DIMM
DM4060-64 64 MB ECC DIMM
NOTE The PM3755U2B controller only accepts DM4050 or DM4060
modules. Do not use non-DPT DIMMs for this controller.
The PM3754U2 controller can use either standard 32- or 36-bit
1
single-
sided, low-profile 60ns (or faster) EDO SIMMs. However, standard EDO
SIMMs do not provide ECC data protection. The PM3754U2 data cache is
protected by ECC only when DPT SM4050 memory modules are installed.
The green ECC Enabled LED is lit when DPT memory is installed. Refer
to Appendix A, Assembly Drawings for the location of this LED.
1
The parity bit is not used on 36-bit EDO SIMMs. However, the SIMMs will function in the controller as