Adapter Configuration and Installation
Configuring SCSI Termination
The devices on each physical end of a SCSI cable must be terminated.
Depending upon how you configure your system, you will either terminate
two SCSI devices, or the SCSI controller and one peripheral SCSI device.
NOTE The SCSI cable supplied with your DPT controller has a
factory-installed active terminator on the end of the cable.
If you are using multiple SCSI busses on a single controller,
each separate bus must be terminated.
SCSI termination for SmartRAID V controllers is configured through the
SMOR utility or from the Configure Host Bus Adapter window in Storage
Manager. The controller has four possible termination settings:
Auto
The default setting. This can be used for all
cabling conditions except where a Narrow (8-bit)
cable is attached to the controller. For this case
use High Only.
Disabled
Turns off controller termination unconditionally.
Enabled
Turns on controller termination unconditionally.
High Only
Terminates only the additional signals that are
used on Wide SCSI devices. This allows Wide and
Narrow cables to be simultaneously attached to
the controller.
By using a 68-pin to 50-pin SCSI cable adapter, an 8-bit SCSI device can be
attached to a Wide SCSI cable along with Wide SCSI devices. However, the
device at the end of the cable must be a Wide SCSI device so that all SCSI
signals are terminated. For internal and external cables where one cable
is an 8-bit (Narrow) SCSI cable, set the controller termination to High
Only.