Acer AR380 F1 Specifications
Technical Specifications
Dimensions
(with bezel)
438.4 (W) x 705 (D) x 88.1 (H) mm ( 17.3 x 27.8 x 3.5 inches)
Form factor
2U rack optimized
Weight
(approximate)
Maximum
(All component slots and sockets
fully populated)
39 kg (88.1 lbs)
Minimum
(One HDD, power supply, and
processor installed)
28.5 kg (62.8 lbs)
BTU rating
Maximum 3276 BTU/hr
System inlet
temperature
Operating 10° - 35° C (50° - 95° F) at sea level wi th an
altitude derating of C per 305 m (1.8° F per 100 0
ft.) above sea level to a maximum of 3050 m
(10,000 ft.) no direct sustained sunlight. Maximum
rate of change is 1
C/hr (18°F/hr). The upper limit
depends on the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
Non-operating -40° - 70° C (-40° - 158° F) Maximum rate of
change is 20°C/hr (36°F/hr).
Relative humidity
(non-condensing)
Operating 8 - 90 % relative humidity (Rh), 28° C (8 2.4° F)
maximum wet bulb temperature, non-condensing
Non-operating 5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing
Acoustic noise
Listed are the declared A-
weighted sound power levels (LWAd) and declared average
bystander position A-weighted sound pressure levels (LpAm) when the product is
operating in a 21° C ambient environment. Noise em issions were measured in
accordance with ISO 7779.
Idle LWAd: 6.4 BA / LpAm: 45.8 dBA
Operating LWAd: 7.2 BA / LpAm: 53.6 dBA
Emissions
classification
(EMC)
FCC rating
Normative standards
Class A
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A
Power
supply
Rated Steady –state power 720 W
Maximum Peak Power 728 W