5
Acer AR380 F1 Specifications
Technical Specifications
(with bezel)
438.4 (W) x 705 (D) x 88.1 (H) mm ( 17.3 x 27.8 x 3.5 inches)
2U rack optimized
(approximate)
Maximum
(All component slots and sockets
fully populated)
39 kg (88.1 lbs)
Minimum
(One HDD, power supply, and
processor installed)
28.5 kg (62.8 lbs)
Maximum 3276 BTU/hr
temperature
Operating 10° - 35° C (50° - 95° F) at sea level wi th an
altitude derating of 1° C per 305 m (1.8° F per 100 0
ft.) above sea level to a maximum of 3050 m
(10,000 ft.) no direct sustained sunlight. Maximum
rate of change is 1
0°C/hr (18°F/hr). The upper limit
depends on the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
Non-operating -40° - 70° C (-40° - 158° F) Maximum rate of
change is 20°C/hr (36°F/hr).
(non-condensing)
Operating 8 - 90 % relative humidity (Rh), 28° C (8 2.4° F)
maximum wet bulb temperature, non-condensing
Non-operating 5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing
Listed are the declared A-
weighted sound power levels (LWAd) and declared average
bystander position A-weighted sound pressure levels (LpAm) when the product is
operating in a 21° C ambient environment. Noise em issions were measured in
accordance with ISO 7779.
Idle LWAd: 6.4 BA / LpAm: 45.8 dBA
Operating LWAd: 7.2 BA / LpAm: 53.6 dBA
classification
(EMC)
FCC rating
Normative standards
Class A
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A
Rated Steady –state power 720 W
Maximum Peak Power 728 W