Smart Server Manager v1.2 – Best Practices
7
route both BMC and OS networking traffic through NIC 1. This method cuts down on the total number of
cables, but can impact the networking performance of the first NIC.
Switch from dedicated to either onboard or failover to use NIC1 as both the management and LAN network
jack.
Note: The core server with SSM installed must be connected to both the dedicated management port and it
NIC1 to monitor itself.
In the BIOS it is important to also watch for the message ‘Update IPMI LAN configuration’. When setting the
IP of the BMC to the desired static IP, the user must change to ‘Yes’ to ensure the IP is changed as desired
when exiting the BIOS.
This item is only available on some of the newer servers beginning with the 2 socket F2 family (i.e. AT350
F2, AR380 F2 and AR360 F2).