Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
: Dark room (<1cd/m2)
Viewing distance
: 40 cm for LCD performance, 20 cm for LCD failures
Warm up time
All specifications :
30 minutes
Fully functional : 5 seconds
Measuring equipment
: Chroma 7120 signal generator or equivalent, directly
Connected to the monitor under test.
Minolta CA100 photometer, or equivalent
Control settings
User brightness control : Set to Factory preset value (cut off raster)
User contrast control : T Set to factory preset value, which allows that the brightest two
of 32 linear distributed gray-scales (0 700mv) can be
distinguished.
User red/white balance,
Green/white balance and
Blue/white balance control :
In the center (unless otherwise specified)
Power input
:
230V± 5,
50±3 Hz
Ambient temperature
:
20+
5
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32
Degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76