Acer Altos R920 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Nein Acer Altos R920 herunter. Acer Altos R920 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 206
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - Acer Altos R920 Series

Acer Altos R920 SeriesUser’s Guide

Seite 2

x• Use the product only with the supplied power supply cord set. If you need to replace the power cord set, make sure that the new power cord meets th

Seite 3 - FCC declaration of conformity

3 System upgrade82Removing and installing a non-hot-plug PCI cardPCI cards installed in slots 1 and 2 are hot-pluggable. If you are adding or removin

Seite 4 - Notice: Peripheral devices

83Configuring server management componentsAltos R920 system provides an upgrade path to advanced server management capabilities through installation o

Seite 5 - Laser compliance statement

3 System upgrade846 Insert the module into the I/O expansion module slot on the mainboard. Make sure that the card is properly seated (D).7 Rotate th

Seite 6 - CE Declaration of conformity

85To remove the I/O expansion module:1 Perform the pre-installation instructions described on page 39.2 Rotate the retention latch on the rear of the

Seite 7

3 System upgrade86Installing and removing the ARMC/3 R2 moduleThe optional ARMC/3 R2 module provides server management firmware and functionality for

Seite 8 - Safety instructions

877 Install the ARMC/3 R2 NIC module.(1) Attach the ARMC/3 R2 NIC module to the I/O expansion module. (2) Secure the ARMC/3 R2 NIC module to the I/O e

Seite 9 - Using electrical power

3 System upgrade8810 Observe the post-installation instructions described on page 40.To remove the ARMC/3 R2 module:1 Perform the pre-installation in

Seite 10 - Product servicing

89Configuring the hardware RAID componentsAltos R920 system supports SAS hardware RAID through installation of of a SAS module. With the addition of t

Seite 11 - Disposal instructions

3 System upgrade905 Align then insert the SAS module in the SAS module slot on the mainboard. Make sure that the edge of the card is properly seated

Seite 12 - Finding your comfort zone

917 Attach the SAS expander cables to the SAS connector A (A) and the SAS connector B (B) on the adapter. 8 Attach the SES cable to the SES connector

Seite 13 - Taking care of your vision

xiDisposal instructions Do not throw this electronic device into the trash when discarding. To minimize pollution and ensure utmost protection of the

Seite 14 - Developing good work habits

3 System upgrade923 Disconnect any cables attached to the SAS module. 4 While pushing back on the slot divider latch, pull the SAS module away from

Seite 15 - Contents

93Installing and removing the RAID activation key and RAID cacheThe optional RAID activation key and RAID cache enables enhanced RAID functionality on

Seite 16 - 4 System BIOS 97

3 System upgrade94To remove the RAID activation key and RAID cache:1 Perform the pre-installation instructions described on page 39.2 Remove the proc

Seite 17 - 5 System troubleshooting 135

95Installing and removing the RAID BBU If power to the SAS controller on the SAS module drops below specifications, the optional RAID BBU maintains th

Seite 18 - Index 185

3 System upgrade96To remove the RAID BBU:1 Perform the pre-installation instructions described on page 39.2 Remove the processor air baffle. Perform

Seite 20

This chapter gives information about the system BIOS and discusses how to configure the system by changing the settings of the BIOS parameters.

Seite 21 - Features summary

99BIOS overviewThe Aptio Setup Utility is a hardware configuration program built into the system's Basic Input/Output System (BIOS). Since most s

Seite 22 - Serial ATA port

4 System BIOS100Entering BIOS setupPower on the server to start the system POST process. During bootup, press F2 to enter the BIOS setup screen. Note

Seite 23 - Control panel

101BIOS setup keyboard commandsUse the following commands to navigate through the Setup Utility.• Left and Right arrow keys - Move between selections

Seite 24 - Operating system and software

xiiTips and information for comfortable use Computer users may complain of eyestrain and headaches after prolonged use. Users are also at risk of phy

Seite 25 - System fan

4 System BIOS102Main menuThe Main menu displays basic and important information about the system. These information are necessary for troubleshooting

Seite 26 - Front bezel

103Processor TypeCore FrequencyCountSpecification of the processor currently installed in the server.Processor clock speed in GHz or MHz.Number of pro

Seite 27 - Front panel

4 System BIOS104Advanced menuThe Advanced menu display submenu options for configuring the function of various hardware components. Select a submenu

Seite 28 - Rear panel

105Processor Configuration Parameter Description OptionCore Frequency Frequency at which the processors currently run in.System Bus FrequencyFrequency

Seite 29 - Internal components

4 System BIOS106Adjacent Cache Line PrefetchWhen enabled, cache lines are fetched in pairs (even line + odd line).When disabled, only the current cac

Seite 30 - System boards

107Memory Configuration Parameter DescriptionTotal Memory Total amount of onboard memory in MB or GB. The memory size is automatically detected by BIO

Seite 31 - * Reserved for tape drives

4 System BIOS108Current ConfigurationDisplays either one of the following memory configuration:• Maximum performance mode - System memory is configur

Seite 32 - Memory board

109Memory RAS and Performance Configuration Parameter Description OptionMemory Mirroring PossibleIndicates if system memory is configured for memory m

Seite 33

4 System BIOS110Snoop Filter The Snoop Filter component monitors and controls the data transactions between memory and the processor.EnabledDisabledF

Seite 34 - Button control panel

111Mass Storage Controller Configuration Parameter Description OptionSAS Option ROMEnables or disables the onboard SAS controller option ROM. EnabledD

Seite 35 - LCD control panel (optional)

xiiiTaking care of your vision Long viewing hours, wearing incorrect glasses or contact lenses, glare, excessive room lighting, poorly focused screens

Seite 36

4 System BIOS112Serial Port ConfigurationParameter Description OptionSerial A Enable Enables or disables the onboard serial A port.EnabledDisabledAdd

Seite 37 - System LED indicators

113USB Configuration IRQ Set the interrupt request line for the serial B port. 34Parameter Description OptionDetected USB DevicesIndicates the number

Seite 38 - Control panel LED indicators

4 System BIOS114Port 60/64 EmulationEnables or disables the I/O port 60/64h emulation support.This parameter is enabled for complete USB keyboard leg

Seite 39

115PCI Configuration Parameter Description OptionMemory Mapped I/O Start AddressSelect the start of the reserved memory region for PCI memory mapped I

Seite 40

4 System BIOS116Dual Monitor VideoSelect a graphic controller as a primary boot device. Note: This parameter will be disabled when the Onboard Video

Seite 41

117LAN Configuration Parameter Description OptionIntel (R) I/OAT Enables or disables the onboard LAN’s I/O Acceleration Technology. The I/O AT accele

Seite 42

4 System BIOS118I/O Riser Board NIC ROMLoad the embedded option ROM for the I/O expansion module network controllers.Note: If disabled, the I/O expan

Seite 43 - LAN port LED indicators

119System Acoustic and Performance Configuration Parameter Description OptionThrottling ModeClosed loop allows the system to achieve higher performanc

Seite 44 - Memory board LED indicators

4 System BIOS120Security menuThe Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. P

Seite 45

121Setting a system password1 Use the up/down keys to highlight a password parameter (Set Administrator Password or Set User Password) then press Ente

Seite 46

xivDeveloping good work habits Develop the following work habits to make your computer use more relaxing and productive: • Take short breaks regularly

Seite 47 - 2 System setup

4 System BIOS122Changing a system password1 Use the up/down keys to highlight either change password parameters (Set Administrator Password or Set Us

Seite 48

123Server Management menuThe Server Management submenu lets you specify the appropriate settings for the system’s event handling function. Parameter D

Seite 49 - Setting up the system

4 System BIOS124FRB-2 Enable When enabled, the BMC (Baseboard Management Controller) will reset the system if BIOS does not complete the POST before

Seite 50 - Connecting peripherals

125Console Redirection Parameter Description OptionConsole RedirectionDefine the serial port used for server management tasks. DisabledSerial Port AS

Seite 51 - Turning on the system

4 System BIOS126* These fields are not shown on the above screenshot.Legacy OS Redirection*Enables or disables the legacy OS redirection (i.e. DOS) o

Seite 52 - Power-on problems

127System InformationThe System Information submenu displays basic information about the server unit.

Seite 53 - Configuring the system OS

4 System BIOS128Intel Remote Management Module InformationThe Remote Management Module submenu displays information about the firmware revisions and

Seite 54 - Turning off the system

129Boot Options menuThe Boot Options menu allows you to set the network device priority during system bootup. It also displays information about the i

Seite 55 - 3 System upgrade

4 System BIOS130Boot Manager menuThe Boot Manager menu lets you set the device priority during system bootup. The server will attempt to boot from th

Seite 56

131Error Manager menuThe Error Manager menu lets you view the system POST errors detected by the system. Parameter Description AttributeError Code

Seite 57 - Installation precautions

ContentsNotices iiiFCC declaration of conformity iiiLaser compliance statement vMacrovision copyright protection notice vCE Declaration of conformi

Seite 58

4 System BIOS132Exit menuThe Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press Enter.

Seite 59 - Opening the server

133Save as User Default ValuesSaves current values to be restored later. Load User Default Values Restores previously saved user default values. Param

Seite 60 - To install the front bezel:

4 System BIOS134Upgrading the BIOSThe upgrade utility allows you to upgrade the BIOS in the flash memory. To prepare to upgrade the BIOS, you need to

Seite 61 - To remove the top cover:

5 System troubleshooting

Seite 62 - To install the top cover:

This chapter provides possible solutions for specific problems. If you cannot correct the problem, contact your local Acer representative or authorize

Seite 63

137TroubleshootingThis chapter helps you identify and solve problems that might occur while you are using the system.For any issue, first ensure that

Seite 64

5 System troubleshooting138First steps checklist• AC power available at the wall outlet?• Are the power supplies plugged in? Check the power cable(s)

Seite 65

139Hardware diagnostic testingThis section provides a more detailed approach to identifying a hardware problem and locating its source.Caution! Before

Seite 66 - Configuring hot-pluggable

5 System troubleshooting140Specific problems and corrective actionsThe following contains specific problems that may arise during the use of your ser

Seite 67 - Determining drive status

141Server boot does not complete POST.Do the following:• Make sure the processor is properly seated. • Check the BIOS release notes to ensure the BIOS

Seite 68 - To install an HDD:

xvi3 System upgrade 37Installation precautions 39ESD precautions 39Pre-installation instructions 40Post-installation instructions 40Opening the serve

Seite 69

5 System troubleshooting142• Check that drive is properly configured.• Check that onboard IDE controller is enabled in the BIOS Setup Utility.ODD tra

Seite 70

143New memory modules installed are not detected. Do the following:• Make sure the memory modules are properly seated on the memory board’s DIMM slots

Seite 71 - Determining fan status

5 System troubleshooting144Diagnostics pass but the connection fails.• Make sure the network cable is securely attached. • Make sure you specify the

Seite 72 - To remove a rear system fan:

145• Try a different version of the software to see if the problem is with the copy you are using. • Make sure all cables are properly connected.• If

Seite 73 - To install a rear system fan:

5 System troubleshooting1462 Verify that the video controller board is fully seated in the mainboard connector.3 Reboot the system for changes to tak

Seite 74

147• Is the fan’s power connector properly connected to the mainboard?• Is the front panel board cable connected to both the mainboard’s front panel b

Seite 75 - To remove a power supply:

5 System troubleshooting148

Seite 76 - To install a power supply:

Appendix A: Rack mount configuration

Seite 77 - Determining PCI slot status

This appendix shows you how to set up the Altos R920 system in a rack mount configuration.

Seite 78 - PCI Add-in Card

151Rack installation informationImportant! Observe the electrostatic discharge (ESD) precautions indicated on page 39 when perfoming the following pro

Seite 79

xviiLAN Configuration 117System Acoustic and Performance Configuration 119Security menu 120Server Management menu 123Console Redirection 125System

Seite 80

Appendix A: Rack mount configuration152• Elevated operating ambient temperature The maximum operating temperature of the system is 35 °C (95°F). Care

Seite 81 - Configuring cold-pluggable

153Rack mount configuration The Altos R920 server system should be mounted into a rack cabinet. A rack rail and CMA (cable management arm) kit is avai

Seite 82 - To remove the DVD drive:

Appendix A: Rack mount configuration154Vertical mounting hole patternThe four vertical rails of the system rack contain mounting holes arranged in a

Seite 83 - To install the DVD drive:

155Installing the system into the rackCaution! To minimize the chances of injuries, make sure that two or more people help in installing the server. T

Seite 84 - Installing a 5.25-inch drive

Appendix A: Rack mount configuration156(3) Do the same thing to the other mounting rail.Caution! To avoid personal injury, care should be taken when

Seite 85

1573 Install the mounting rails to the rack posts. (1) Determine the vertical position in the rack. Refer to “Vertical mounting hole pattern” on page

Seite 86 - Upgrading the processor

Appendix A: Rack mount configuration158(6) Fully extend the mounting rails on the rack.

Seite 87 - Server Board Cutaway

1594 Install the server into the rack.Caution! To avoid personal injury, care should be taken when pressing the inner rail release latches and sliding

Seite 88

Appendix A: Rack mount configuration1605 Attach the CMA (cable management arm) to the rear of the server.The CMA allows you to tie-wrap all cables to

Seite 89 - To remove a proces s o r :

161(6) Connect the power, peripheral and networking cables into their appropriate ports. Refer to “Connecting peripherals” on page 32 for detailed ins

Seite 90

xviiiSAS configuration utility 180SAS RAID configuration utility 182Index 185

Seite 91

Appendix A: Rack mount configuration162

Seite 92

Appendix B: Memory configuration

Seite 93

This chapter provides details on how to configure the system memory boards. Recommended memory board and FBDIMM installation order and FBDIMM populati

Seite 94

165IntroductionThe system’s memory architecture supports up to four memory boards organized by branches and channels. The MCH (memory controller hub)

Seite 95

Appendix B: Memory configuration166The memory boards connect to the mainboard through the memory board slots A, B, C, and D (Each slot support the x1

Seite 96 - DIMM population guidelines

167FBDIMM module population order Single and dual channel populationThe tables below list the suggested FBDIMM module population for normal configurat

Seite 97

Appendix B: Memory configuration168Population with four memory boardsDIMM slot Memory board A Memory board B Memory board C Memory board DTota l mem

Seite 98 - DIMM and insert it again

169Memory sparing populationThe tables below list the suggested FBDIMM module population for memory sparing configuration.Population with two memory b

Seite 99

Appendix B: Memory configuration170Memory mirroring populationThe table below list the suggested FBDIMM module population for memory mirroring config

Seite 100 - 3 System upgrade

171Memory configurationThe BIOS configures the system memory into the best possible configuration after comparing the current FBDIMM population with t

Seite 101

1 System tour

Seite 102

Appendix B: Memory configuration1727 Press Y to confirm. The server reboots to activate the changes. Single-channel mode Single-channel mode is a fai

Seite 103

173Memory sparing mode Sparing is only supported in a lock-stepped (dual-channel) configuration. Memory sparing is the use of a lock-stepped FBDIMM ra

Seite 104

Appendix B: Memory configuration174Dual-ranked memory sparingWhen a dual-ranked FBDIMM is used as spare, the BIOS can independently select a physical

Seite 105 - Network I/O Expansion Module

175Memory mirroring modeMemory mirroring is a high availability mode providing a redundant image of the system memory. Two identical images of memory

Seite 106

Appendix B: Memory configuration1765 Set the Select Memory RAS Configuration to Mirroring. 6 Return to the Memory Configuration menu option. • Make

Seite 107 - To install the SAS module:

Appendix C: SAS and SAS RAID configuration utilities

Seite 108

This appendix gives an overview of the RAID configuration utilities supported by your server.

Seite 109 - To remove the SAS module:

179OverviewThe system may be equipped with a SAS or SAS RAID configuration utility (depending on your system configuration). You can use these utiliti

Seite 110

Appendix C: SAS and SAS RAID configuration utilities180SAS configuration utilityThis section briefly shows how to create mirror with LSI 1078 integr

Seite 111

181Initializing the RAID volumeYou can skip this procedure if you selected to create a new IM array (or pressed D) while performing the creating a RAI

Seite 112

Changes may be made periodically to the information in this publication without obligation to notify any person of such revision or changes. Such cha

Seite 113 - To install the RAID BBU:

The Altos R920 is a powerful, feature-rich platform designed to deliver superior performance, scalability, and flexibility to meet the needs of variou

Seite 114 - To remove the RAID BBU:

Appendix C: SAS and SAS RAID configuration utilities182SAS RAID configuration utility This section briefly shows how to launch the SAS RAID configur

Seite 115 - 4 System BIOS

18311 Now you can reboot the system and install the Operating System. Select Exit and click Yes.12 Press <Ctrl+Alt+Del> to reboot the system.Ass

Seite 116 - BIOS parameters

Appendix C: SAS and SAS RAID configuration utilities184

Seite 117 - BIOS overview

185IndexNumerics5.25-inch driveinstalling 66AARMC/3 R2specifications 5ARMC/3 R2 moduleinstalling 86removing 88BBIOS menusAdvancedLAN Confi

Seite 118 - Entering BIOS setup

186DVD drive 65front bezel 42front system fan assembly 53HDD 50hot-plug PCI card 62I/O expansion module 83memory board 76non-hot-

Seite 119 - BIOS setup keyboard commands

187SSAS moduleinstalling 89removing 91setting up the system 31preinstallation requirements 31specificationchipset 3control panel 5gr

Seite 121

3Features summaryThis section lists the impressive computing features of the Altos R920 system.Processor• Supports one to four physical processors• Qu

Seite 122 - Advanced menu

1 System tour4• Memory reliability, availability, and serviceability (RAS) features - Memory scrub engine- Memory mirroring - Memory sparingNote: For

Seite 123 - Processor Configuration

5Networking• Intel ESB2 I/O controller• Intel 82563EB Gigabit Ethernet controller with dual ports• Intel 82575 Gigabit Ethernet controller with dual p

Seite 124

1 System tour6I/O ports•Front • VGA/monitor port• Three USB 2.0 ports•Rear• Serial port • VGA/monitor port• Two USB 2.0 ports• Four Gigabit LAN ports

Seite 125 - Memory Configuration

7Power supply • Two 110/220-volts,1570-watt hot-swap (1+1) redundant power supply modules System fan• Two hot-swap redundant front system fan modules

Seite 126

1 System tour8External and internal structureFront bezelThe front bezel provides an interface for system management via status LED indicators. The li

Seite 127

9Front panel Item Icon ComponentA DVD drive bayB 5.25-inch drive baysC VGA/monitor portD USB 2.0 portsE Control panelF Hot-swap system fan modulesG H

Seite 128

1 System tour10Rear panel * Reserved for remote management of server. This requires installation of an ARMC/3 R2module.Item ComponentA1 - A7 A1 Hot

Seite 129

11Internal components Item ComponentA DVD drive bayB Processor air baffleC Memory boardD Plastic PCI slot divider and PCI slotsE Rear system fan m

Seite 130 - Serial Port Configuration

iiiNoticesFCC declaration of conformityThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) t

Seite 131 - USB Configuration

1 System tour12System boardsMainboardThe mainboard becomes accessible once you open the system. It should look like the figure shown below.Item Descr

Seite 132

13* Reserved for tape drives.C PCI Express x8 (with x4 throughput) - (slot 7)R CPU socket 1D Serial port A (internal) S CPU socket 2E PCI Express x8 (

Seite 133 - PCI Configuration

1 System tour14Memory boardThe memory board connects to the mainboard through x16 PCI Express slots. Item Description Item DescriptionA Power good

Seite 134

15Control panelThe Altos R920 system supports either the button control panel, providing basic functionality, or the LCD control panel, which adds add

Seite 135 - LAN Configuration

1 System tour16Button control panel Item Icon ComponentA HDD (hard disk drive) activity indicator B LAN1 status indicator displays network activity i

Seite 136

17LCD control panel (optional) Item Icon ComponentA LCD displayB Scroll up buttonC Scroll down buttonD Back buttonE Select buttonF System ID indicator

Seite 137

1 System tour18Control panel button function overviewThe following table list and describe the function of the control buttons available on the contr

Seite 138 - Security menu

19System LED indicatorsThis section describes the different LED indicators located on• Control panel• Hot-plug HDD carrier• Hot-swap fan module• Hot-p

Seite 139 - Setting a system password

1 System tour20Control panel LED indicators The following table list and describe the LED indicators available on the mini or optional full-function

Seite 140 - Changing a system password

21B LAN1, LAN2 status Green On • LAN1 active•LAN2 active• Network activity in either LAN ports on the mainboard.• Network activity in either LAN ports

Seite 141 - Server Management menu

ivHowever, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radi

Seite 142

1 System tour22Hot-plug HDD carrier LED indicators D Power — Off Power off System is not powered on. Green On Power on System has power applied to

Seite 143 - Console Redirection

23Hot-swap fan module LED indicatorsB Green On HDD is installed and working correctly.Flashing HDD is active.Off • No HDD is installed.• HDD is initi

Seite 144

1 System tour24Hot-plug power supply module LED indicatorsItemLED indicatorColor Status DescriptionA Power good Green On System has power applied to

Seite 145 - System Information

25LAN port LED indicatorsHot-plug PCI Express slot LED indicatorsThe PCI slots 1 and 2 have a LED indicator to display the PCI hot-plug status. ItemLE

Seite 146 - 4 System BIOS

1 System tour26Memory board LED indicatorsThe LEDs on the memory board indicate the status of the memory board power and DIMM. Attention Off Normal N

Seite 147 - Boot Options menu

27System jumpers Item Name Location Default SettingsA Rolling BIOS J3D1 1-2 (Empty)2-3 (Stuff)Force other bankNormal modeB Password disable or clearJ3

Seite 148 - Boot Manager menu

1 System tour28E BMC flash write protectJ6D1 1-2 (Stuff)2-3 (Empty)Disable flash write protectEnable flash write protectF Circuit breaker J6F1 1-2 (E

Seite 150 - Exit menu

This chapter gives you instructions on how to set up the system. Procedures on how to connect peripherals are also explained.

Seite 151 - Parameter Description

31Setting up the systemPre-installation requirementsSelecting a siteBefore unpacking and installing the system, select a suitable site for the system

Seite 152 - Upgrading the BIOS

vRemarque à l'intention des utilisateurs canadiens Cet appareil numérique de la classe A est conforme a la norme NMB-003 du Canada. Laser complia

Seite 153 - 5 System

2 System setup32Connecting peripheralsRefer to the illustration below for specific connection instructions on the peripherals you want to connect to

Seite 154

33Turning on the systemAfter making sure that you have properly set up the system, applied power, and connected all the necessary peripherals, you can

Seite 155 - Troubleshooting

2 System setup34Note: If the system does not turn on or boot after pressing the power button, go to the next section for the possible causes of the b

Seite 156 - First steps checklist

35Configuring the system OSThe Altos R920 system comes with Acer EasyBUILD that allows you to conveniently install your choice of operating system. To

Seite 157 - Hardware diagnostic testing

2 System setup36Turning off the systemThere are two ways to turn off the server—via software or via hardware. The software procedure below applies to

Seite 159

This chapter discusses the precautionary measures and installation procedures you need to know to upgrade the system.

Seite 160 - ODD drive cannot read a disc

39Installation precautionsBefore you install any server component, we recommend that you read the following sections. These sections contain important

Seite 161 - Problems with the network

3 System upgrade40Pre-installation instructions Perform the steps below before you open the server or before your remove or replace any component.War

Seite 162

41Opening the serverCaution! Before you proceed, make sure that you have turned off the system and all peripherals connected to it. Read the “Pre-inst

Seite 163

viCE Declaration of conformityWe, Acer Computer (Shanghai) Limited3F, No. 168 Xizang Medium Road, Huangpu District,Shanghai, ChinaContact Person: Mr.

Seite 164

3 System upgrade42To install the front bezel:Slide the front bezel onto the chassis.

Seite 165

43Removing and installing the top coverTo remove the top cover:1 Perform the pre-installation instructions described on page 39.2 Loosen the two capti

Seite 166

3 System upgrade44To install the top cover:1 Perform the pre-installation instructions described on page 39.2 Place the top cover on the chassis so t

Seite 167 - Appendix A: Rack

45Removing and installing the processor air baffleTo remove the processor air baffle:You will need to remove the processor air baffle to perform the f

Seite 168

3 System upgrade46To install the processor air baffle:1 Perform the pre-installation instructions described on page 39.2 Insert the front of the proc

Seite 169 - Rack installation information

473 Lower the rear of the baffle into place (A), making sure the guides on each side of the air baffle will correctly engage in the left and right cha

Seite 170

3 System upgrade48Configuring hot-pluggable componentsHot-pluggable components are the components that can be removed and replaced while the system i

Seite 171 - Rack mount configuration

49Removing and installing a hard disk driveThe system supports eight hot-plug drive carriers. Each carrier holds a standard 2.5-inch SAS hard drive. N

Seite 172

3 System upgrade505 Pull the lever and slide the carrier from the chassis (B). 6 Place the HDD carrier on a clean, static-free work surface. 7 If you

Seite 173

512 Remove the four screws that secure the air baffle to the HDD carrier (A). 3 Remove the air baffle from the HDD carrier (B).4 Save the air baffle a

Seite 174

viiDeclaration of conformity for EU countriesHereby, Acer, declares that this PC series is in compliance with the essential requirements and other rel

Seite 175

3 System upgrade528 Use the lever to push the HDD carrier until it docks into place, then close the HDD carrier lever (B). 9 Setup the new hard drive

Seite 176

53Determining fan statusEach fan or fan assembly has an amber LED to indicate a failed fan condition. If the amber LED is on, the fan assembly needs t

Seite 177

3 System upgrade543 Push the handle closed until it clicks into place (B). To remove a rear system fan:1 Perform the pre-installation instructions de

Seite 178

55To install a rear system fan:Warning! To ensure proper system cooling, the replacement of a failed system fan module should be completed within one

Seite 179

3 System upgrade56Removing and installing a power supplyThe server has two power supply bays on the rear panel that accept hot-swap redundant power s

Seite 180

57To remove a power supply:Caution: Power supply hot-swap operations should be performed only if a failure occurs in the power supply. 1 Observe the E

Seite 181 - Appendix B: Memory

3 System upgrade58To install a power supply:1 If necessary, remove the old power supply. See previous section.2 With the handle in the open position,

Seite 182

59Removing and installing a PCI cardImportant: Only PCI add-in cards in PCI slots 1 and 2 are hot-pluggable. If you are installing or removing a PCI c

Seite 183 - Introduction

3 System upgrade605 Open the yellow caution plate (A).6 Rotate the slot retention latch on the rear of the card slot upward (B). 7 Release the vertic

Seite 184

61Note: Press the attention button again within five seconds to abort the hot-plug operation. 3 Make sure that the power LED on the rear of the PCI sl

Seite 185

viiiInformation for your safety and comfort Safety instructionsRead these instructions carefully. Keep this document for future reference. Follow all

Seite 186

3 System upgrade62To install a new hot-plug PCI card: 1 If your server is operating, use your OS to power down the PCI slot. 2 Perform the pre-instal

Seite 187 - Memory sparing population

63Configuring cold-pluggable componentsCold-pluggable components are the components that require the system to be powered down before you can remove o

Seite 188 - Memory mirroring population

3 System upgrade64Removing and installing the DVD driveTo remove the DVD drive:1 Perform the pre-installation instructions described on page 39.2 Dis

Seite 189 - Memory configuration

657 Observe the post-installation instructions described on page 40.To install the DVD drive:1 Perform the pre-installation instructions described on

Seite 190 - Single-channel mode

3 System upgrade66Installing a 5.25-inch driveThe 5.25-inch drive bay allows you to install a tape drive to provide the system with additional storag

Seite 191 - Memory sparing mode

677 Slide the 5.25-inch peripheral device into the server until it clicks into place. 8 Observe the post-installation instructions described on page 4

Seite 192 - Dual-ranked memory sparing

3 System upgrade68Upgrading the processorThe server supports up to four processors, the following models are supported.• Quad-core Intel Xeon process

Seite 193 - Memory mirroring mode

693 Remove the thermal blank. (1) Loosen the four screws on the thermal blank. (2) Pull the thermal blank away from the CPU socket. (3) Store the ther

Seite 194

3 System upgrade70(2) Position the processor over the socket, matching the two triangle markers (A) and lining up the processor pins with the socket

Seite 195 - SAS RAID

71(2) Tighten the screws in the order shown, approximately one full turn at a time until each is evenly tightened. Do not fully tighten one screw at a

Seite 196

ix• Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short-out parts that could re

Seite 197 - Overview

3 System upgrade72(2) Pull the heat sink away from the CPU socket. (3) Lay down the heat sink in an upright position—with the thermal patch facing up

Seite 198 - SAS configuration utility

73(2) Pull out the processor from the socket. (3) Store it in an antistatic bag.5 If you are not installing a new processor, reinstall the processor t

Seite 199 - Initializing the RAID volume

3 System upgrade74Removing and installing a memory board assemblyThe server supports up to four memory boards. At least one memory board and two FBDI

Seite 200

752 Lift the latches on the memory board to disengage the memory board from the mainboard (A). 3 Lift the memory board by the latches (B).4 Observe th

Seite 201 - Assigning a hot spare disk

3 System upgrade76To install the memory board assembly:1 Perform the pre-installation instructions described on page 39.2 Locate an empty memory boar

Seite 202

77Installing and removing DIMM modulesThe server’s memory board supports eight DIMM slots. Each slot supports 1 GB, 2 GB, and 4 GB DDR2-667 (PC2-5300)

Seite 203

3 System upgrade78DIMM population guidelinesThe following rules apply when adding DIMMs to the memory boards.• DIMMs must be populated beginning with

Seite 204

79To install DIMMs in the memory board:Caution! Use extreme care when installing a DIMM. Applying too much pressure can damage the connector. DIMMs ar

Seite 205

3 System upgrade805 Open the clips on the DIMM slot(s) (A). 6Align (B) then insert the DIMM into the socket (C). 7 Push down on the top edge of the D

Seite 206

81To remove DIMMs on the memory board:Before you can install a new DIMM in a socket, remove first any previously installed DIMM from that socket. Impo