Seite 1 - Altos S700 Series

Altos S700 SeriesUser’s Guide

Seite 2

xImportant safety informationOnly a technically qualified person shall access, integrate, configure, and service this product.Intended application use

Seite 3 - Contents

Appendix A Safety Statement Translations84 Hvis der i mere end ét udstyrsrackkabinet er indbyrdes forbundet udstyr, bør disse kabinetter have samme gr

Seite 4 - Contentsiv

85 Før det blir gjort forsøk på installere eller fjerne komponenter, må det tas forholdsregler for å avverge statisk elektrisitet. Minimumskravet er r

Seite 5

Appendix A Safety Statement Translations86 Når hylle for rackmontering blir installert eller fjernet, må alle strømforsyninger og diskstasjoner fjerne

Seite 6 - Contentsvi

87 Nach dem Entfernen des LS Module muss die entstehende Lücke durch eine Blende oder durch die Installation eines anderen LS Module geschlossen werde

Seite 7 - Audience

Appendix A Safety Statement Translations88WarningA possible shock hazard may exist in the area of the fan connection. Im Bereich des Lüftungsanschluss

Seite 8 - FCC notice

Appendix BTechnical Specifications

Seite 9 - Notice: Canadian users

Appendix B Technical Specifications90Technical SpecificationsHost Interface• Two Fibre Channel interfaces, 200MB\s each, 400 MB\s total.• External hub

Seite 10 - Important safety information

91Rack EnclosureHeight: 5.22 inches (13.3cm)Width: 17.5 inches (44.5cm)Depth: 20 inches (50.8cm)Weight: 60 lbs (29.5kg) maximumWarrantyThree (3) years

Seite 11 - Precautionary reminders

Appendix B Technical Specifications92Disk DrivesPower SupplyAC Power Supply InputTemperature• Operating Temperature: 5oC to 40oC• Temperature Storage:

Seite 12 - Equipment rack precautions

93• Altitude Storage: -200 to 40,000 feetOperational ShockHalf sine shock: 3G half sine shock with a pulse duration of 11 milliseconds or less. No per

Seite 13 - Important safety instructions

xiMultiple power cordsWarning! To avoid electrical shock, disconnect all AC power cords before accessing inside the system.Earth grounded socket-out

Seite 14

Appendix B Technical Specifications94Immunity Testing: Light Industry CENELEC EN 50 082-1, 1997• Electrostatic Discharge CENELEC EN 61000-4-2, 1995• R

Seite 15 - European Community Statement

Appendix CConfiguration Loop Diagram

Seite 16

Appendix C Configuration Loop Diagram96Loop Diagram for a Single Enclosure System - Single Loop 345678910111213141516ExternalCircles denote disk drive

Seite 17 - Introduction

97Loop Diagram for a Dual Enclosure System - Single Loop345678910111213141516ExternalCircles denote disk drives with drive ID shown.1819 2021222324252

Seite 18

Appendix C Configuration Loop Diagram98Loop Diagram for a Single Enclosure System - Dual Loop345678910111213141516External Circles denote disk drives

Seite 19

99Loop Diagram for a Dual Enclosure System - Dual Loop345678910111213141516ExternalCircles denote disk drives with drive ID shown.1819 202122232425262

Seite 20 - Features

Appendix C Configuration Loop Diagram100

Seite 21 - Cooling System

Appendix DUpgrading an Altos S700 JBOD Array to a RAID Array

Seite 22 - I/O Option Modules

In this section the procedure for upgrading a Altos S700 Series Storage Array from a JBOD system to a RAID system is described. The equipment and part

Seite 23 - Altos S700 RAID Controller

103Equipment and parts necessary for upgradeThe following is a list of the equipment and parts required for the upgrade from JBOD to RAID:• Anti-stati

Seite 24 - Chapter 1 Introduction8

xiiEquipment rack precautionsFollow the rack manufacturer's safety and installation instructions for proper rack installation. The following add

Seite 25

Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array1045 If you are upgrading to a dual RAID configuration then repeat steps 2 through 4 to i

Seite 26 - Chapter 1 Introduction10

105Follow this procedure to install the Battery Backup Unit (BBU):1 Remove the ACM from the enclosure by loosening the two ACM screws and using the ha

Seite 27 - Installation and Setup

Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array106

Seite 28

107IndexAadvanced cooling module, leds, 68advanced cooling modules, 5, 78,79air flow, 16ambient temperature, 16audience, viiBbattery

Seite 29 - Safety Statements

108spin up sequence 58Ttechnical specifications, 90temperature, 16, 92terminal emulation 44Uunpacking, 15Vvibration, operational,

Seite 30

xiiiImportant safety instructionsRead these instructions carefully. Save these instructions for future reference.1 Follow all warnings and instructio

Seite 31 - Unpacking and Initial Setup

xivd If the product does not operate normally when the operating instructions are followed. Adjust only those controls that are covered by the operat

Seite 32 - Mechanical Loading

xvEuropean Community StatementThis equipment complies with the following European directives:EMC Directive 89/336/EEC and amending Directives 92/31/EE

Seite 35 - (2Gb or 1Gb)

This Chapter introduces the Altos S700 Series. The main features of the Series are described along with a list of the models that are available.

Seite 36

3IntroductionThe Altos S700 Series provides a highly flexible, high performance storage solution that evolves to meet your changing needs. Based on a

Seite 37 - (Quad Loop)

Changes may be made periodically to the information in this publication without obligation to notify any person of such revision or changes. Such cha

Seite 38 - 3 Replace the LS module

Chapter 1 Introduction4Features• Redundant data paths with dual-ported fibre drives and dual (200MB/s) fibre channel loops for a total of 400 MB/s.•

Seite 39 - Configuration Rules

5Caution: Power supply cords shall have conductors with a cross-sectional area not less than 4mm2. This cross-sectional area corresponds to a minimum

Seite 40 - Supported Host Bus Adapters

Chapter 1 Introduction6I/O Option ModulesThe two rear I/O option slots (A and B) can contain a range of different option modules. The LS module will

Seite 41 - Supported Cables

7I/O Expansion Module- Optical/OpticalThis 2Gb FC expansion module has two SFF LC optical connectors. The top connector is the FC Loop Input port and

Seite 42 - Optical Cables

Chapter 1 Introduction8Figure 1-1: Altos S700 Series Tower Model

Seite 43 - JBOD Configurations

9Figure 1-2: Altos S700 Series Rack Model

Seite 44

Chapter 1 Introduction10

Seite 45 - Setting the Enclosure ID

Chapter 2 Installation and Setup

Seite 46 - Enclosure ID

This Chapter describes the installation and set up of the Altos S700 Series. Important safety instructions are discussed along with the electrical, me

Seite 47

13Safety StatementsThe following safety statements must be read before you install or operate the Altos S700 Series. For language translations of thes

Seite 48 - Configurations

Preface viiAudience viiConventions Used In This User Guide viiEuropean Community Statement xvIntroduction 3Features 4Disk Drive Carrier 4Power Supplie

Seite 49

Chapter 2 Installation and Setup14Warning: A possible shock hazard may exist in the area of the fan connection.Warning: Disconnect the power cords be

Seite 50

15Unpacking and Initial SetupWhen you receive your system, visually inspect the exterior of the packaging for any signs of damage. If any damage is fo

Seite 51 - Quad Loop Configuration

Chapter 2 Installation and Setup16Installing the System in an Equipment RackBefore installing the Altos S700 Series in an equipment rack, it is essen

Seite 52

17least one other person when installing an enclosure. This is necessary to prevent personal injury and damage to the enclosure.

Seite 53 - Connecting an AC Power Source

Chapter 2 Installation and Setup18Electrical ConsiderationsWhen installing the Altos S700 Series the following electrical considerations must be appl

Seite 54 - Disk Drive Spin Up Sequence

19Setting Fibre Channel Loop Speed (2Gb or 1Gb)The Altos S700 Series can be operated with fibre channel loop speeds of either 2Gb (default) or 1Gb. Th

Seite 55 - RAID Configurations

Chapter 2 Installation and Setup20Figure 2-1 Location of Jumpers on LS Module

Seite 56

21Split Fibre Channel Loop Operation (Quad Loop)Note: Quad Loop is only available on JBOD systemsThe Altos S700 Series LS module allows for split FC L

Seite 57

Chapter 2 Installation and Setup223 Replace the LS module.

Seite 58

23Configuration RulesThese rules must be applied when implementing the Altos S700 Series configurations:• When daisy chaining, both 2Gb enclosures mus

Seite 59 - I/O Circuit Board

ContentsivRAID Controller Status LEDs 46RAID Controller Configurations 47Setting the Enclosure ID 48Configurations 51Single RAID Controller Configurat

Seite 60 - RS232 Serial Port

Chapter 2 Installation and Setup24Supported Host Bus AdaptersContact your sales person for a list of approved Host Bus Adapters.

Seite 61 - RAID Controller Location

25Supported CablesWarning: Only the following APPROVED cables must be used with the Altos S700 Series enclosures.This section lists the cables that mu

Seite 62 - RAID Controller Status LEDs

Chapter 2 Installation and Setup26Optical CablesThe following Fibre Channel Optical cables are available from Acer. Please contact your sales person

Seite 63

Chapter 3JBOD Configurations

Seite 64

This Chapter describes the procedure for connecting your Altos S700 Series JBOD system to a host computer(s). Detailed information on how to configure

Seite 65

29Setting the Enclosure IDEach of the fourteen disk drive slots of the Altos S700 Series has a unique identifier assigned to it. This identifier is as

Seite 66 - 0 1 2 3 4 5 6

Chapter 3 JBOD Configurations30Figure 3-1 Location of Enclosure ID SwitchThis enclosure ID switch can be set to 0 through 7.The graphic below shows

Seite 67

31The fourteen disk drive slots (0 to 13), will be assigned an identifier based on the enclosure ID and the slot number as shown below.Enclosure ID Dr

Seite 68

Chapter 3 JBOD Configurations32ConfigurationsThis section describes the procedures for cabling the main configurations of the Altos S700 Series JBOD.

Seite 69

33JBOD ConfigurationsThere are two JBOD configurations covered in this Installation Guide:• Dual FC Loop mode (including how to daisy chain enclosures

Seite 70

vDisk Drives 92Power Supply 92Temperature 92Humidity 92Altitude 92Operational Shock 93Operational Vibration 93Regulatory Agency Compliance 93Equipment

Seite 71

Chapter 3 JBOD Configurations34Figure 3-2 Connecting dual FC Loop configuration to a hostSee Appendix C for Loop Diagram.To daisy chain enclosures

Seite 72

35Figure 3-3 Daisy chaining dual FC Loop enclosuresSee Appendix C for Loop Diagram.Caution: When daisy chaining enclosures, you must ensure that eac

Seite 73

Chapter 3 JBOD Configurations36This section describes the procedure for connecting the enclosure in quad loop mode. For this configuration there must

Seite 74

37Connecting a Power SourceThe Altos S700 enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However,

Seite 75 - System Monitoring

Chapter 3 JBOD Configurations38Disk Drive Spin Up SequenceAt power on, the LS module will perform its internal start up initialization routine. Then

Seite 76

Chapter 4RAID Configurations

Seite 77 - Overview

This chapter describes how to set up, configure and use the Altos S700 Series RAID Controller. Some general information about the RAID controller is a

Seite 78 - LS Module

41Altos S700 Series RAID Controller IntroductionThe Altos S700 RAID Controller is a high performance controller, providing two host fibre channel and

Seite 79 - Altos S700 Enclosure LEDs

Chapter 4 RAID Configurations42The controller, I/O, and ethernet circuit boards are assembled into a stack with the controller and ethernet boards mo

Seite 80 - Description Color Indication

43RAID Controller Circuit BoardsThis section gives a brief description of the RAID controller circuit boards that are inside the RAID controller modul

Seite 82

Chapter 4 RAID Configurations44The I/O circuit board has two SFF optical transceivers supporting shortwave multimode fibre on the host side and a 90-

Seite 83 - Power OK

45RAID Controller LocationThe RAID controller is installed in the rear of the enclosure in the location shown in Figure 4-2.Figure 4-2 RAID Controll

Seite 84

Chapter 4 RAID Configurations46RAID Controller Status LEDsThe RAID controller has 7 Status LEDs as shown above. describes what these LEDs signify.Co

Seite 85 - RAID Controller LEDs

47RAID Controller ConfigurationsThis section describes how to cable the two standard RAID controller configurations: Single RAID Controller and Dual R

Seite 86

Chapter 4 RAID Configurations48Setting the Enclosure IDEach of the fourteen disk drive slots of the Altos S700Altos S700 Series has a unique identifi

Seite 87 - Removing Components

49The graphic below shows the slot number and location.The fourteen disk drive slots (0 to 13), will be assigned an identifier based on the enclosure

Seite 88

Chapter 4 RAID Configurations50Slot 13 16 31 46 61 76 91 106 121Enclosure ID Drive Slot 0 1 2 3 4 5 67

Seite 89 - Location of the Components

51ConfigurationsThis section shows how to connect the RAID enclosures to a host system(s). The procedure for daisy chaining the enclosures together is

Seite 90 - Removing a Disk Drive Carrier

Chapter 4 RAID Configurations52Figure 4-5 Single RAID Controller to Host ConnectorDaisy Chaining a Single Controller EnclosureTo daisy chain the RA

Seite 91 - Cam Lever

53Figure 4-6 Daisy Chaining Single Controller EnclosureCaution: When daisy chaining enclosures, you must ensure that each enclosure has a unique Enc

Seite 92 - Removing an LS Module

viiPrefaceThis Installation Guide describes the installation and operation of the Altos S700 Series. The following products are covered: AS.S7001.001,

Seite 93

Chapter 4 RAID Configurations54Dual RAID Controller ConfigurationIn this configuration two RAID Controllers are installed in the enclosures I/O slots

Seite 94 - Removing a Power Supply

55Figure 4-7 Dual RAID Controller ConfigurationDaisy Chaining a Dual Controller EnclosureTo daisy chain the RAID enclosure to an expansion enclosure

Seite 95 - Cooling Module

Chapter 4 RAID Configurations56Figure 4-8 Daisy Chaining a Dual Controller EnclosureCaution: When daisy chaining enclosures, you must ensure that e

Seite 96 - Module/RAID Controller

57Connecting a Power SourceThe Altos S700 enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However,

Seite 97 - Translations

Chapter 4 RAID Configurations58Disk Drive Spin Up SequenceAt power on, the LS module will perform its internal start up initialization routine. Then

Seite 98 - Caution:

Chapter 5System Monitoring

Seite 99

This Chapter describes the devices used to monitor the Altos S700 Series. The location of the monitoring LEDs and how to interpret them is described.

Seite 100

61OverviewThe front mounted LS module is the main monitoring device of the Altos S700 Series. This module is complemented by status and fault LEDs, mo

Seite 101

Chapter 5 System Monitoring62LS ModuleThe LS Module (Loop Resiliency and SES Module) provides monitoring and control for the Altos S700 Series. The m

Seite 102

63Altos S700 Enclosure LEDsThe Altos S700 Series has six LEDs located on each of the front mounted LS Modules. These LEDs show the status of the enclo

Seite 103

viiiNoticesFCC noticeThis device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules

Seite 104

Chapter 5 System Monitoring64The table below shows the meaning of each of the LEDs, and how to interpret them.Note: If enabled, the audible alarm wil

Seite 105 - Technical Specifications

65Disk Drive LEDsEach disk drive carrier has two LED indicators visible from the front of the Altos S700 enclosure. The green disk drive ready LED is

Seite 106

Chapter 5 System Monitoring66Figure 5-2 Disk Drive Carrier LEDs18FDisk Drive Ready(Green)BiColor LED(Green/Amber)

Seite 107 - Failure Notification

67Power Supply LEDsThe Altos S700 Series uses two AC power supplies. The AC power supplies provide 853W peak output power and 673W continuous output p

Seite 108 - Temperature

Chapter 5 System Monitoring68Advanced Cooling Module (ACM) LEDsThe Altos S700 Series has two variable speed fans per advanced cooling module. Each of

Seite 109 - Regulatory Agency Compliance

69RAID Controller LEDsThe RAID controller has 7 LEDs located and numbered as shown.Figure 5-5 RAID controller LEDsThe table below describes the LEDs

Seite 110 - Electromagnetic Radiation

Chapter 5 System Monitoring70

Seite 111 - Configuration Loop Diagram

Chapter 6Installing and Removing Components

Seite 112 - Enclosure ID 0

This Chapter describes the procedures for installing and removing the replaceable components in the Altos S700 Series.Warning: The module handles are

Seite 113 - Enclosure ID 1

73Location of the Components12120I0IDisk DrivesACMsPower SuppliesI/O Module/I/O Module/ModuleLSModuleRAID ControllerRAID Controller

Seite 114

ixUse conditionsThis part complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause

Seite 115

Chapter 6 Installing and Removing Components74Installing and Removing a Disk Drive CarrierThe disk drive carriers are located in the front of the enc

Seite 116

75Figure 6-1 Disk Drive Carrier18FCam LeverPush locking tab in this direction to open

Seite 117 - JBOD Array to a RAID Array

Chapter 6 Installing and Removing Components76Installing and Removing an LS ModuleThe LS Modules are located in the front of the enclosure. Follow th

Seite 118

77Figure 6-2 LS Module012345Cam LeverPush locking tab in this direction to open

Seite 119 - • Phillips head screw driver

Chapter 6 Installing and Removing Components78Installing and Removing a Power SupplyThe power supplies are located in the rear of the enclosure. Foll

Seite 120

79Installing and Removing an Advanced Cooling ModuleThe advanced cooling modules are located in the rear of the enclosure. Follow these procedures to

Seite 121

Chapter 6 Installing and Removing Components80Installing and Removing an I/O Module/RAID ControllerNote: In the following section, “I/O Module” is ta

Seite 122

Appendix ASafety Statement Translations

Seite 123

Appendix A Safety Statement Translations82Caution:This equipment is intended only for installation in a restricted access location.Caution: Dieses Ger

Seite 124

83 Låt skivdrivenheter och strömtillförsel nå rumstemperatur innan strömförsörjningen slås på. Ennen kuin kytket virran hyllyyn sijoitettuihin levyase