Acer AT350 F1 Specifications
Power Supply Specification
720W Power Supply
Operational
Input Voltage
Range (Vrms)
100 to 240 VAC
Frequency
Range
(Nominal) (Hz)
50 / 60
Nominal Input
Voltage (Vrms)
100 120 208 200 220 230 240
Max. Rated
Output Wattage
720 720 720 720 720 720 720
Nominal Input
Current (A rms)
8.6114 7.0132 3.951 4.0993 3.7458 3.5995 3.4697
Max. Rated
Input Wattage
Rating (Watts)
851.6 837.58 811.51 811.88 809.78 808.82 807.77
Max. Rated VA
(Volt-Amp)
859.0739 841.0282 822.7821 821.1591 825.2115 828.9638 834.0423
Efficiency (%) at
Max. Rated
Output Wattage
84.55% 85.96% 88.72% 88.68% 88.91% 89.02% 89.13%
Power Factor
0.9913 0.9959 0.9863 0.9887 0.9813 0.9757 0.9685
Leakage
Current (mA)
Less
than 3.5
Less than
3.5
Less than
3.5
Less than
3.5
Less than
3.5
Less than
3.5
Less
than 3.5
Max. Inrush
Current (A
peak)
Less
than 25A
Less than
25A
Less than
25A
Less than
25A
Less than
25A
Less than
25A
Less
than 25A
Max. Inrush
Current
Duration (mS)
Less
than 10
Less than
10
Less than
10
Less than
10
Less than
10
Less than
10
Less
than 10
Max. British
Thermal Unit
Rating (BTU/hr.)
2903.956 2856.148 2767.249 2768.511 2761.35 2758.076 2754.496
1 KW = 3412 BTU/hr.