Troubleshooting
Problem: The SmartRAID V controller I
2
O BIOS reports the drive as a disk instead
of a drive.
Solution: This typically happens when a drive that is attached to a SmartRAID V
controller has been formatted with a sector size other than 512 bytes . Use
Storage Manager or SMOR to reformat the drive with 512 byte sectors.
This can also occur if the drive is the 9
th
or higher logical drive attached to
the controller.
NOTE Using SMOR to set Bootable Devices to Disabled as in the
previous problem will result in the same symptoms. If you
require access to disk drives connected to the SmartRAID V
controller during the boot process, change Bootable Devices to
Normal.
Problem: Although the SCSI devices can be accessed by the SmartRAID V
controller, the fault LEDs on the devices in a RAIDstation storage cabinet
do not flash during boot-up and the SmartRAID V controller does not
detect drive swaps or cabinet failures.
Solution: These symptoms indicate that the RAIDstation storage cabinet status
signals are not being properly received by the SmartRAID V controller.
For DEC Fault Bus subsystems: this can be caused by another SCSI
device or non-DPT cabinet connected to the external SCSI cable along
with the RAIDstation cabinet. Other devices will typically ground these
signals.
For SAF-TE or SES: this can result from a failed enclosure monitoring
module in the subsystem cabinet.
Problem: After updating the SmartRAID V controller firmware or BIOS and
rebooting, the adapter does not respond.
Solution: The update may have been unsuccessful. The controller is now in a state
in which it hangs the system during boot. If this happens, the parameters
in the NVRAM can be restored to their default settings using the following
procedure:
1. Turn off power to the system.
2. Place a shorting jumper across pins 1 and 2 of P4 on the controller.
3. Power on the system and wait until the LEDs 3, 5, 7 and 8 on the
controller begin flashing.
4. Turn off power to the system and remove the jumper.
You can now reconfigure the controller using SMOR or Storage Manager.